Two different smartwatches exhibit high accuracy in evaluating heart rate and peripheral oxygen saturation in cats when compared with the electrocardiography and transmittance pulse oximetry

Author:

Yanmaz Latif Emrah1,Okur Sitkican2,Ersoz Ugur2,Senocak Mumin Gokhan2,Turgut Ferda2

Affiliation:

1. Department of Surgery, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur, Turkey

2. Department of Surgery, Faculty of Veterinary Medicine, Atatürk University, Erzurum, Turkey

Abstract

Abstract OBJECTIVE To evaluate the accuracy for 2 smartwatches with oximetry technology and optical wrist heart rate (HR) or single-lead Electrocardiography (ECG) technology (Fenix 5X Plus [GF5xp], Garmin Ltd and Apple Watch 6 [AppW6], Apple Inc, respectively) versus reference methods (ECG and transmittance pulse oximetry [TPO], respectively) in measuring HR and peripheral oxygen saturation of hemoglobin (SpO2) in cats. ANIMALS 10 male client-owned cats aged 8 to 12 months and weighing 3.2 to 4.5 kg. PROCEDURES All cats that were presented for elective castration at the Atatürk University Animal Hospital between March 10 and April 15, 2022, were considered for enrollment. Monitoring of HR and SpO2 during anesthesia was performed with a 3-lead ECG and transmittance pulse oximetry, respectively, connected to a multiparameter monitor (reference methods) along with a GF5xp and a AppW6. Agreement between reference methods and the smartwatches were assessed by the Bland-Altman plot, in which the differences (%) between methods were plotted against their mean HR or SpO2 (reference method measurement – test device measurement) and the limits of agreement (mean ± 1.96 × SD). RESULTS Compared with ECG measurements of HR, GF5xp had superior bias (–0.1%) and limit of agreement (LoA, 3.0 to –3.3%) versus those of the AppW6 (bias, 0.2%; LoA, 3.7 to –3.4%). Compared with TPO measurements of SpO2, AppW6 had superior bias (0.2%) and LoA (3.0% and –2.5%) versus those of the GF5xp (bias, –2.1%; LoA, 0.2 to –4.4%). CLINICAL RELEVANCE Results indicated that the GF5xp and AppW6 exhibited high accuracy in evaluating HR and SpO2 in cats when compared with the reference methods. However, it should be noted that these comparisons were made in anesthetized patients without any systemic disease.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary

Reference21 articles.

1. Risk factors, clinical signs, and survival in cats with a clinical diagnosis of idiopathic hypertrophic cardiomyopathy: 74 cases (1985–1989);Atkins CE,1992

2. Evaluating veterinarians’ and veterinary students’ knowledge and clinical use of pulse oximetry;Hoffmeister EH,2005

3. Evaluation of pulse oximetry as a surrogate for PaO2 in awake dogs breathing room air and anesthetized dogs on mechanical ventilation;Farrell KS,2019

4. Pulse oximetry and capnometry;Thawley V,2013

5. Wearable and nearable biosensors and systems for healthcare;Rienzo MD,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3