A comparison of patient-specific and conventional instrumentation for total knee arthroplasty

Author:

Abane L.1,Anract P.1,Boisgard S.2,Descamps S.2,Courpied J. P.1,Hamadouche M.1

Affiliation:

1. Hôpital Cochin, APHP, Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France.

2. Centre Hospitalier Régional Universitaire de Clermont Ferrand, 58 Boulevard de Montalembert, 63003, Clermont Ferrand, France.

Abstract

In this study we randomised 140 patients who were due to undergo primary total knee arthroplasty (TKA) to have the procedure performed using either patient-specific cutting guides (PSCG) or conventional instrumentation (CI). The primary outcome measure was the mechanical axis, as measured at three months on a standing long-leg radiograph by the hip–knee–ankle (HKA) angle. This was undertaken by an independent observer who was blinded to the instrumentation. Secondary outcome measures were component positioning, operating time, Knee Society and Oxford knee scores, blood loss and length of hospital stay. A total of 126 patients (67 in the CI group and 59 in the PSCG group) had complete clinical and radiological data. There were 88 females and 52 males with a mean age of 69.3 years (47 to 84) and a mean BMI of 28.6 kg/m2 (20.2 to 40.8). The mean HKA angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4 to 183.4) in the PSCG group (p = 0.34). Outliers were identified in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%) in the PSCG group (p = 0.99). There was no significant difference in the clinical results (p = 0.95 and 0.59, respectively). Operating time, blood loss and length of hospital stay were not significantly reduced (p = 0.09, 0.58 and 0.50, respectively) when using PSCG. The use of PSCG in primary TKA did not reduce the proportion of outliers as measured by post-operative coronal alignment. Cite this article: Bone Joint J 2015;97-B:56–63.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference43 articles.

1. Health-Related Quality of Life in Total Hip and Total Knee Arthroplasty

2. No authors listed. Swedish knee arthroplasty register. Annual report 2012. http://www.myknee.se/pdf/117_SKAR_2012_Engl_1.0.pdf (date last accessed 14 November 2014).

3. No authors listed. The Norwegian arthroplasty register annual report 2010. http://nrlweb.ihelse.net/eng/Report_2010.pdf (date last accessed 27 October 2014).

4. Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements

5. The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional Varus

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3