Effect of Surgeon Volume on Mechanical Complications after Resection Arthroplasty with Articulating Spacer

Author:

Ko Chih-Yuan12,Tsai Chun-Hao13,Fong Yi-Chin13,Chen Hui-Yi4ORCID,Chen Hsien-Te13,Lin Tsung-Li123ORCID

Affiliation:

1. Department of Orthopedics, China Medical University Hospital, Taichung 40447, Taiwan

2. Graduate Institute of Biomedical Sciences, China Medical University, Taichung 40402, Taiwan

3. Department of Sports Medicine, College of Health Care, China Medical University, Taichung 40604, Taiwan

4. Department of Radiology, China Medical University Hospital, Taichung 40447, Taiwan

Abstract

Two-stage revision with an antibiotic-loaded cement articulating spacer is a standard treatment for chronic prosthetic knee infection (PKI); however, mechanical complications can occur during the spacer period. There is limited evidence on the association between surgeon volume and mechanical complications after resection arthroplasty (RA) using an articulating spacer. This study aimed to compare the rates of mechanical complications and reoperation after RA with articulating spacers by surgeons with high volumes (HV) and low volumes (LV) of RA performed and analyzed the risk factors for mechanical failure. The retrospective study investigated 203 patients treated with PKIs who underwent RA with articulating spacers and were divided according to the number of RAs performed by the surgeons: HV (≥14 RAs/year) or LV (<14 RAs/year). Rates of mechanical complications and reoperations were compared. Risk factors for mechanical complications were analyzed. Of the 203 patients, 105 and 98 were treated by two HV and six LV surgeons, respectively. The mechanical complication rate was lower in HV surgeons (3.8%) than in LV surgeons (36.7%) (p < 0.001). The reoperation rate for mechanical complications was lower in HV surgeons (0.9%) than in LV surgeons (24.5%) (p < 0.001). Additionally, 47.2% of patients required hinge knees after mechanical spacer failure. Medial proximal tibial angle < 87°, recurvatum angle > 5°, and the use of a tibial spacer without a cement stem extension were risk factors for mechanical complications. Based on these findings, we made the following three conclusions: (1) HV surgeons had a lower rate of mechanical complications and reoperation than LV surgeons; (2) mechanical complications increased the level of constraint in final revision knee arthroplasty; and (3) all surgeons should avoid tibial spacer varus malalignment and recurvatum deformity and always use a cement stem extension with a tibial spacer.

Funder

China Medical University Hospital

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3