Can a gait-dependent model predict wear on retrieved total knee arthroplasty components?

Author:

Knowlton Christopher B.1,Lundberg Hannah J.1,Wimmer Markus A.1,Jacobs Joshua J.1

Affiliation:

1. Rush University Medical Center, Chicago, Illinois, USA

Abstract

Aims A retrospective longitudinal study was conducted to compare directly volumetric wear of retrieved polyethylene inserts to predicted volumetric wear modelled from individual gait mechanics of total knee arthroplasty (TKA) patients. Methods In total, 11 retrieved polyethylene tibial inserts were matched with gait analysis testing performed on those patients. Volumetric wear on the articular surfaces was measured using a laser coordinate measure machine and autonomous reconstruction. Knee kinematics and kinetics from individual gait trials drove computational models to calculate medial and lateral tibiofemoral contact paths and forces. Sliding distance along the contact path, normal forces and implantation time were used as inputs to Archard’s equation of wear to predict volumetric wear from gait mechanics. Measured and modelled wear were compared for each component. Results Volumetric wear rates on eight non-delaminated components measured 15.9 mm3/year (standard error (SE) ± 7.7) on the total part, 11.4 mm3/year (SE ± 6.4) on the medial side and 4.4 (SE ± 2.6) mm3/year on the lateral side. Volumetric wear rates modelled from patient gait mechanics predicted 16.4 mm3/year (SE 2.4) on the total part, 11.7 mm3/year (SE 2.1) on the medial side and 4.7 mm3/year (SE 0.4) on the lateral side. Measured and modelled wear volumes correlated significantly on the total part (p = 0.017) and the medial side (p = 0.012) but not on the lateral side (p = 0.154). Conclusion In the absence of delamination, patient-specific knee mechanics during gait directly affect wear of the tibial component in TKA. Cite this article: Bone Joint J 2020;102-B(6 Supple A):129–137.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference45 articles.

1. The John Insall Award: Patient Expectations Affect Satisfaction with Total Knee Arthroplasty

2. Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?

3. Patient‐Specific Functional Analysis: The Key to the Next Revolution Towards the Treatment of Hip and Knee Osteoarthritis

4. The influence of design, materials and kinematics on the in vitro wear of total knee replacements

5. International Organization for Standardization. ISO 14243-3:2014 - Implants for surgery – Wear of total knee-joint prostheses – Part 3: Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test. https://www.iso.org/standard/56649.html (date last accessed 2 April 2020).

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3