Influence of the trigger technique on ventricular function measurements using 3-Tesla magnetic resonance imaging: comparison of ECG versus pulse wave triggering

Author:

Sievers Burkhard12,Wiesner Marco2,Kiria Nino2,Speiser Uwe2,Schoen Steffen2,Strasser Ruth H2

Affiliation:

1. Division of Cardiology, Pulmology and Vascular Medicine, University Hospital, Duesseldorf

2. Department of Cardiology, Heart Center Dresden, University Hospital, University of Technology Dresden, Dresden, Germany

Abstract

Background Three Tesla cardiovascular magnetic resonance imaging (3T-CMR) is increasingly used in clinical practice. Despite many advantages one drawback is that ECG signal disturbances and artifacts increase with higher magnetic field strength resulting in trigger problems and false gating. This particularly affects cardiac imaging because most pulse sequences require ECG triggering. Pulse wave (PW) triggering is robust and might have advantages over ECG triggering. Purpose To evaluate differences in left ventricular (LV) function as an integral part of most CMR studies between ECG- and PW-triggered short-axis imaging using 3T-CMR. Material and Methods Forty-three patients underwent multiple short-axis cine imaging for LV-function assessment with ECG and PW triggering using standard multibreath hold steady-state free precession. LV-volumes (EDV, ESV), ejection fraction (EF), and mass were determined by slice summation. LV-wall motion was assessed by using a 4-point scoring scale. Bland Altman statistics for inter-observer variability were performed. Results ECG triggering failed in 15 patients (34.8%). Thus, analysis was performed in 28 patients (13 with impaired LV function). Difference in volumes (EDV 0.13 ± 1.8 mL, ESV 0.59 ± 1.1 mL), EF (–0.32 ± 0.6%) and mass (0.01 ± 1.1 g) between ECG and PW triggering were very small and significant only for ESV and EF (p ≤ 0.011). In patients with impaired LV function ( n = 19) differences were not significant (p ≥ 0.128). Wall motion scores did not differ between ECG and PW triggering (p ≥ 0.295). Inter-observer variability for function measurements was low. Conclusion Short-axis cine imaging for LV-function assessment can accurately be performed using PW triggering on 3T magnets, and may be used in clinical practice when ECG triggering is disturbed.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3