Plasma sphingosine-1-phosphate measurement in healthy subjects: close correlation with red blood cell parameters

Author:

Ohkawa Ryunosuke1,Nakamura Kazuhiro1,Okubo Shigeo1,Hosogaya Shigemi2,Ozaki Yukio2,Tozuka Minoru1,Osima Noriko3,Yokota Hiromitsu1,Ikeda Hitoshi14,Yatomi Yutaka14

Affiliation:

1. Department of Clinical Laboratory, The University of Tokyo Hospital, Tokyo, Japan

2. Department of Clinical and Laboratory Medicine, Faculty of Medicine, University of Yamanashi, Yamanashi, Japan

3. Department of Biomolecular Science, Faculty of Science, Toho University, Chiba, Japan

4. Department of Clinical Laboratory Medicine, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan

Abstract

Background Since sphingosine-1-phosphate (Sph-1-P) plays an important role as an extracellular mediator through interaction with specific cell surface receptors, especially in the area of vascular biology and immunology/haematology, determination of its plasma concentration may become important from the clinical viewpoint. Thus, we attempted to develop a method of measuring the plasma Sph-1-P concentration for use in the clinical laboratory setting. Methods After two-step lipid extraction, Sph-1-P was coupled with o-phthaldialdehyde, and the resultant fluorescent derivative was separated by high-performance liquid chromatography. C17-Sph-1-P was used as the internal standard, instead of dihydrosphingosine-1-phosphate, which had been used previously for the same purpose but was actually detected in plasma. Results Our procedures for preparing the plasma samples and assay Sph-1-P were found to be satisfactory for clinical laboratory testing. The plasma Sph-1-P concentrations were significantly higher in men (413.1 ± 52.0 nmol/L; mean ± SD) than in women (352.4 ± 39.7 nmol/L). Unexpectedly, strong positive correlations were found between the plasma Sph-1-P concentration and red blood cell (RBC)-related parameters, rather than platelet-related parameters. Conclusions Our present study confirmed the possibility of the clinical introduction of plasma Sph-1-P measurement, and in addition, suggested that RBCs may be involved in the regulation of plasma Sph-1-P concentrations.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 75 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3