Application of five frozen human-pooled serum samples assigned by the International Federation of Clinical Chemistry and Laboratory Medicine reference procedure in a traceability investigation of γ-glutamyltransferase catalytic concentration measurements in China

Author:

Xia Changyu1,Tong Qing2,Wang Qingtao2,Tang Zhuling3,Qi Lili4,Chi Shan5,Zhang Man5,Wang Xuejing1,Li Haixia1,Xu Guobin1

Affiliation:

1. Clinical Laboratory Department, Peking University First Hospital

2. Clinical Laboratory Department, Beijing Chaoyang Hospital, Beijing

3. Clinical Laboratory Department, The Affiliated Hospital of Guiyang Medical College, Guizhou

4. Biosino Bio-technology and Science Inc

5. Clinical Laboratory Department, Beijing Shijitan Hospital, Beijing, China

Abstract

Background The in vitro directive of the European Union requires traceability to the international recommended reference procedures. The application of the reference procedures is necessary in order to evaluate the accuracy of γ-glutamyltransferase (GGT) assays of routine measurement systems in China. Methods Five frozen patient-pooled serum samples were assigned values by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure in order to evaluate the traceability of the results of GGT catalytic activity from six homogeneous systems. One of the serum samples was used to calibrate seven non-homogeneous systems. Results All of the homogeneous systems, except the Dade system (Dade Bering Inc, IL, USA), achieved traceability within the measurement range. The Roche and Hitachi systems were better than the other systems. After calibration, the variance of the non-homogeneous systems decreased dramatically from between 14.50% and 25.23% to between 1.25% and 3.09% and the bias decreased from between −11.4% and −4.1% to between 0.5% and 3.5%. Conclusion Manufacturers in China should ensure that their calibration systems correspond to the IFCC reference procedures. Fresh frozen pooled patient serum assigned by reference laboratories can be used to calibrate non-homogeneous systems in order to achieve traceability.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3