Progress and impact of enzyme measurement standardization

Author:

Infusino Ilenia,Frusciante Erika,Braga Federica,Panteghini Mauro

Abstract

AbstractInternational Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has established reference measurement procedures (RMPs) for the most popular enzymes. Manufacturers should assign values to commercial calibrators traceable to these RMPs to achieve equivalent results in clinical samples, independent of reagent kits, instruments, and laboratory where the measurement is carried out. The situation is, however, far from acceptable. Some manufacturers continue to market assays giving results that are not traceable to internationally accepted RMPs. Meanwhile, end-users often do not abandon assays with demonstrated insufficient quality. Of the enzyme measurements, creatine kinase (CK) is satisfactorily standardized and a substantial improvement in performance of marketed γ-glutamyltranspeptidase (GGT) assays has been demonstrated. Conversely, aminotransferase measurements often exceed the desirable analytical performance because of the lack of pyridoxal-5-phosphate addition in the commercial reagents. Measurements of lactate dehydrogenase (LDH), alkaline phosphatase (ALP), and α-amylase (AMY) still show major disagreement, suggesting the need for improvement in implementing traceability to higher-order references. This is mainly the result of using assays with different analytical selectivities for these enzymes. The definition by laboratory professionals of the clinically acceptable measurement uncertainty for each enzyme together with the adoption by EQAS of commutable materials and use of an evaluation approach based on trueness represent the way forward for reaching standardization in clinical enzymology.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference84 articles.

1. Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European Federation of Clinical Chemistry and Laboratory Medicine;Clin Chem Lab Med,2015

2. Commutability study on candidate materials for three new enzyme certified reference materials;Clin Chem Lab Med,2014

3. Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project;Clin Chim Acta,2006

4. A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase;Clin Chem Lab Med,2013

5. Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European Federation of Clinical Chemistry and Laboratory Medicine;Clin Chem Lab Med,2015

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3