Powered ankle exoskeletons reveal the metabolic cost of plantar flexor mechanical work during walking with longer steps at constant step frequency

Author:

Sawicki Gregory S.1,Ferris Daniel P.1

Affiliation:

1. Human Neuromechanics Laboratory, University of Michigan at Ann Arbor, Ann Arbor, MI 48109, USA

Abstract

SUMMARYWe examined the metabolic cost of plantar flexor muscle–tendon mechanical work during human walking. Nine healthy subjects walked at constant step frequency on a motorized treadmill at speeds corresponding to 80% (1.00 m s–1), 100% (1.25 m s–1), 120% (1.50 m s–1) and 140% (1.75 m s–1) of their preferred step length (L*) at 1.25 m s–1. In each condition subjects donned robotic ankle exoskeletons on both legs. The exoskeletons were powered by artificial pneumatic muscles and controlled using soleus electromyography (i.e. proportional myoelectric control). We measured subjects' metabolic energy expenditure and exoskeleton mechanics during both unpowered and powered walking to test the hypothesis that ankle plantarflexion requires more net metabolic power (W kg–1) at longer step lengths for a constant step frequency (i.e. preferred at 1.25 m s–1). As step length increased from 0.8 L* to 1.4 L*, exoskeletons delivered ∼25% more average positive mechanical power (P=0.01; +0.20±0.02 W kg–1to +0.25±0.02 W kg–1, respectively). The exoskeletons reduced net metabolic power by more at longer step lengths (P=0.002;–0.21±0.06 W kg–1 at 0.8 L* and–0.70±0.12 W kg–1 at 1.4 L*). For every 1 J of exoskeleton positive mechanical work subjects saved 0.72 J of metabolic energy (`apparent efficiency'=1.39) at 0.8 L* and 2.6 J of metabolic energy (`apparent efficiency'=0.38) at 1.4 L*. Declining ankle muscle–tendon `apparent efficiency' suggests an increase in ankle plantar flexor muscle work relative to Achilles' tendon elastic energy recoil during walking with longer steps. However, previously stored elastic energy in Achilles' tendon still probably contributes up to 34% of ankle muscle–tendon positive work even at the longest step lengths we tested. Across the range of step lengths we studied, the human ankle muscle–tendon system performed 34–40% of the total lower-limb positive mechanical work but accounted for only 7–26% of the net metabolic cost of walking.

Publisher

The Company of Biologists

Subject

Insect Science,Molecular Biology,Animal Science and Zoology,Aquatic Science,Physiology,Ecology, Evolution, Behavior and Systematics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3