Speech Recognition as a Function of the Number of Electrodes Used in the SPEAK Cochlear Implant Speech Processor

Author:

Fishman Kim E.1,Shannon Robert V.1,Slattery William H.1

Affiliation:

1. House Ear Institute Los Angeles, CA

Abstract

Speech recognition was measured in listeners with the Nucleus-22 SPEAK speech processing strategy as a function of the number of electrodes. Speech stimuli were analyzed into 20 frequency bands and processed according to the usual SPEAK processing strategy. In the normal clinical processor each electrode is assigned to represent the output of one filter. To create reduced-electrode processors the output of several adjacent filters were directed to a single electrode, resulting in processors with 1, 2, 4, 7, 10, and 20 electrodes. The overall spectral bandwidth was preserved, but the number of active electrodes was progressively reduced. After a 2-day period of adjustment to each processor, speech recognition performance was measured on medial consonants, vowels, monosyllabic words, and sentences. Performance with a single electrode processor was poor in all listeners, and average performance increased dramatically on all test materials as the number of electrodes was increased from 1 to 4. No differences in average performance were observed on any test in the 7-, 10-, and 20-electrode conditions. On sentence and consonant tests there was no difference between average performance with the 4-electrode and 20-electrode processors. This pattern of results suggests that cochlear implant listeners are not able to make full use of the spectral information on all 20 electrodes. Further research is necessary to understand the reasons for this limitation and to understand how to increase the amount of spectral information in speech received by implanted listeners.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing,Linguistics and Language,Language and Linguistics

Reference34 articles.

1. Forward masking patterns in electrical stimulation: Dependence on stimulus parameters;Chatterjee M.;In Abstracts of the Twentieth Midwinter Meeting, Association for Research in Otolaryngology,,1997

2. Analysis of electrode pair confusions and implications for speech recognition in cochlear implant listeners;Collins L.;In Abstracts of the Seventeenth Midwinter Meeting, Association for Research in Otolaryngology,,1994

3. Development of the Profile of Hearing Aid Performance (PHAP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3