Validation of a Novel Wearable Electromyography Patch for Monitoring Submental Muscle Activity During Swallowing: A Randomized Crossover Trial

Author:

Kantarcigil Cagla12,Kim Min Ku3,Chang Taehoo4,Craig Bruce A.5,Smith Anne1,Lee Chi Hwan36,Malandraki Georgia A.13ORCID

Affiliation:

1. Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, IN

2. Department of Communication Sciences and Disorders at Northwestern University, Evanston, IL

3. School of Biomedical Engineering, Purdue University, West Lafayette, IN

4. School of Materials Engineering, Purdue University, West Lafayette, IN

5. Department of Statistics, Purdue University, West Lafayette, IN

6. School of Mechanical Engineering, Purdue University, West Lafayette, IN

Abstract

Purpose Surface electromyography (sEMG) is often used for biofeedback during swallowing rehabilitation. However, commercially available sEMG electrodes are not optimized for the head and neck area, have rigid form, and are mostly available in large medical centers. We developed an ultrathin, soft, and flexible sEMG patch, specifically designed to conform to the submental anatomy and which will be ultimately incorporated into a telehealth system. To validate this first-generation sEMG patch, we compared its safety, efficiency, and signal quality in monitoring submental muscle activity with that of widely used conventional sEMG electrodes. Method A randomized crossover design was used to compare the experimental sEMG patch with conventional (snap-on) sEMG electrodes. Participants completed the same experimental protocol with both electrodes in counterbalanced order. Swallow trials included five trials of 5- and 10-ml water. Comparisons were made on (a) signal-related factors: signal-to-noise ratio (SNR), baseline amplitude, normalized mean amplitude, and sEMG burst duration and (b) safety/preclinical factors: safety/adverse effects, efficiency of electrode placement, and satisfaction/comfort. Noninferiority and equivalence tests were used to examine signal-related factors. Paired t tests and descriptive statistics were used to examine safety/preclinical factors. Results Forty healthy adults participated (24 women, M age = 67.5 years). Signal-related factors: SNR of the experimental patch was not inferior to the SNR of the conventional electrodes ( p < .0056). Similarly, baseline amplitude obtained with the experimental patch was not inferior to that obtained with conventional electrodes ( p < .0001). Finally, normalized amplitude values were equivalent across swallows (5 ml: p < .025; 10 ml: p < .0012), and sEMG burst duration was also equivalent (5 ml: p < .0001; 10 ml: p < .0001). Safety/preclinical factors: The experimental patch resulted in fewer mild adverse effects. Participant satisfaction was higher with the experimental patch ( p = .0476, d = 0.226). Conclusions Our new wearable sEMG patch is equivalent with widely used conventional sEMG electrodes in terms of technical performance. In addition, our patch is safe, and healthy older adults are satisfied with it. With lessons learned from the current COVID-19 pandemic, efforts to develop optimal swallowing telerehabilitation devices are more urgent than ever. Upon further validation, this new technology has the potential to improve rehabilitation and telerehabilitation efforts for patients with dysphagia. Supplemental Material https://doi.org/10.23641/asha.12915509

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing,Linguistics and Language,Language and Linguistics

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3