Chemometric Tools in the Analysis of Pharmaceutics Samples: a Comparison Among Several Multivariate Calibration Methods

Author:

Ornelas-Soto Nancy E.1,Duarte-Moller José Alberto2,Amador-Hernández Judith3,Rivera-Gomez Alma Rocío4,Contreras Rafael Pacheco ,2,Ochoa Rolando Flores2,Villegas Ignacio Yocupicio ,2,López-De-Alba Pedro L.5

Affiliation:

1. Centro del Agua para América Latina y el Caribe, ITESM, Monterrey, N.L., 64849 México.

2. Universidad de Sonora. Unidad

3. Facultad de Ciencias Químicas, Universidad Autónoma de Coahuila, Saltillo, Coah., 25280 México.

4. Tecnológico Nacional de México. Chihuahua, Ave. Tecnológico 2909, Chihuahua, Chih.31310.

5. Universidad de La Salle Bajío. Ave. Universidad 602. Lomas del Campestre. León Gto. 37150. México

Abstract

Bivariate calibration algorithm is compared with the results obtained by the usage of high-dimensional calibration methods such as partial least squares (PLS) and multi-way partial least-squares (N-PLS) by using UV-Vis spectrophotometric data of first and second-order. The algorithms were applied to the determination of a mixture of an analgesic and a stimulant compound and their actual concentrations of them were calculated by using spectroscopic data. The direct reading of absorbance values at 227 nm and 271 nm were employed for quantification of the compounds in the case of the bivariate method. The approaches of first-order and multi-way methods were applied with a previous optimization of the calibration matrix by constructing sets of calibration and validation with 20 and 10 samples (mixtures) respectively according to a central composite design and their UV absorption spectra were recorded at 200-350 nm. All algorithms were satisfactorily applied to the simultaneous determination of these compounds in pharmaceutical formulations with mean percentage recovery of 100.5 ± 3.67, 98.7 ± 3.42, and 100.5 ± 3.74 for bivariate, PLS-1, and N-PLS, respectively. The statistical evaluation of the bivariate method showed that this procedure is comparable with those algorithms that employ high-dimensional structured information. The aim of the work is to compare the methods under study and it can be seen that there are no significant differences, so a simple spectrophotometer can be used up to a very specialized one. However, the advantage of bivariate calibration is its simplicity, due to the minimal experimental manipulation.

Publisher

North Atlantic University Union (NAUN)

Subject

General Biochemistry, Genetics and Molecular Biology,Biomedical Engineering,General Medicine,Bioengineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3