Multi-organ segmentation of CT via convolutional neural network: impact of training setting and scanner manufacturer

Author:

Weisman Amy JORCID,Huff Daniel TORCID,Govindan Rajkumar Munian,Chen SongORCID,Perk Timothy GORCID

Abstract

Abstract Objective. Automated organ segmentation on CT images can enable the clinical use of advanced quantitative software devices, but model performance sensitivities must be understood before widespread adoption can occur. The goal of this study was to investigate performance differences between Convolutional Neural Networks (CNNs) trained to segment one (single-class) versus multiple (multi-class) organs, and between CNNs trained on scans from a single manufacturer versus multiple manufacturers. Methods. The multi-class CNN was trained on CT images obtained from 455 whole-body PET/CT scans (413 for training, 42 for testing) taken with Siemens, GE, and Phillips PET/CT scanners where 16 organs were segmented. The multi-class CNN was compared to 16 smaller single-class CNNs trained using the same data, but with segmentations of only one organ per model. In addition, CNNs trained on Siemens-only (N = 186) and GE-only (N = 219) scans (manufacturer-specific) were compared with CNNs trained on data from both Siemens and GE scanners (manufacturer-mixed). Segmentation performance was quantified using five performance metrics, including the Dice Similarity Coefficient (DSC). Results. The multi-class CNN performed well compared to previous studies, even in organs usually considered difficult auto-segmentation targets (e.g., pancreas, bowel). Segmentations from the multi-class CNN were significantly superior to those from smaller single-class CNNs in most organs, and the 16 single-class models took, on average, six times longer to segment all 16 organs compared to the single multi-class model. The manufacturer-mixed approach achieved minimally higher performance over the manufacturer-specific approach. Significance. A CNN trained on contours of multiple organs and CT data from multiple manufacturers yielded high-quality segmentations. Such a model is an essential enabler of image processing in a software device that quantifies and analyzes such data to determine a patient’s treatment response. To date, this activity of whole organ segmentation has not been adopted due to the intense manual workload and time required.

Funder

AIQ Solutions

Publisher

IOP Publishing

Subject

General Nursing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Quantitative evaluation of lesion response heterogeneity for superior prognostication of clinical outcome;European Journal of Nuclear Medicine and Molecular Imaging;2024-05-31

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3