Evaluation of manual and automated approaches for segmentation and extraction of quantitative indices from [18F]FDG PET-CT images

Author:

Krokos GeorgiosORCID,Kotwal Tejas,Malaih Afnan,Barrington Sally,Jackson Price,Hicks Rodney J,Marsden Paul K,Fischer Barbara Malene

Abstract

Abstract Utilisation of whole organ volumes to extract anatomical and functional information from computed tomography (CT) and positron emission tomography (PET) images may provide key information for the treatment and follow-up of cancer patients. However, manual organ segmentation, is laborious and time-consuming. In this study, a CT-based deep learning method and a multi-atlas method were evaluated for segmenting the liver and spleen on CT images to extract quantitative tracer information from Fluorine-18 fluorodeoxyglucose ([18F]FDG) PET images of 50 patients with advanced Hodgkin lymphoma (HL). Manual segmentation was used as the reference method. The two automatic methods were also compared with a manually defined volume of interest (VOI) within the organ, a technique commonly performed in clinical settings. Both automatic methods provided accurate CT segmentations, with the deep learning method outperforming the multi-atlas with a DICE coefficient of 0.93 ± 0.03 (mean ± standard deviation) in liver and 0.87 ± 0.17 in spleen compared to 0.87 ± 0.05 (liver) and 0.78 ± 0.11 (spleen) for the multi-atlas. Similarly, a mean relative error of −3.2% for the liver and −3.4% for the spleen across patients was found for the mean standardized uptake value (SUVmean) using the deep learning regions while the corresponding errors for the multi-atlas method were −4.7% and −9.2%, respectively. For the maximum SUV (SUVmax), both methods resulted in higher than 20% overestimation due to the extension of organ boundaries to include neighbouring, high-uptake regions. The conservative VOI method which did not extend into neighbouring tissues, provided a more accurate SUVmax estimate. In conclusion, the automatic, and particularly the deep learning method could be used to rapidly extract information of the SUVmean within the liver and spleen. However, activity from neighbouring organs and lesions can lead to high biases in SUVmax and current practices of manually defining a volume of interest in the organ should be considered instead.

Funder

National Institute for Health and Care Research

Wellcome Trust

Publisher

IOP Publishing

Subject

General Nursing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3