Author:
Kokkrathoke S,Yachum N,Chunjarean S,Manasatitpong K
Abstract
Abstract
Linear accelerator (LINAC) has been broadly used in various applications in recent years. For instance, the LINAC can produce X-rays and high-energy electrons, which are utilised in radiation therapy for medical purposes and also applied to fruit steriliser for exportation. At present, the prototype of the 6 MeV LINAC for fruit irradiation by using a magnetron radio frequency (RF) source has been developed at Synchrotron Light Research Institute (SLRI) in Nakhon Ratchasima, Thailand. The LINAC consists of several key sub-systems such as pulsed modulators both for electron gun and magnetron used to power the LINAC, magnetic guidance and beam diagnostic systems. All these have been integrated and worked in proper function to reach a proper and stable RF acceleration. Therefore, a timing system is required with well synchronisation for precise transfer of the clock and reference trigs to each sub-system. Furthermore, the low-cost in-house synchronous equipment has been built here for domestic researchers when they would like to apply this system to their work in the future; consequently, the FPGA-based system for real-time synchronisation has been created to achieve the sequences of the LINAC timing system. In this design, the Zybo Z7 development board from the Xilinx Zynq-7000 family is chosen, which integrates the programmable logic (PL) and processing system (PS) in the same chip. The experimental results are presented by the LINAC operation with synchronisation between a precise time and various delay times on both pulsed modulators, which the synchronous technique with accurate time demonstrates excellent performances leading to stable X-ray radiation for fruit irradiation with synchronous operation between the electron gun and magnetron.
Subject
Computer Science Applications,History,Education
Reference6 articles.
1. Review of industrial application of electron accelerators;Mehnert;Nucl. Instrum. Methods. Phys. Res. B,1996
2. Effects of X-ray treatments on pathogenic bacteria, inherent microflora, color, and firmness on whole cantaloupe;Barakat;Int. J. Food Microbiol.,2012
3. Food irradiation using bremsstrahlung X-rays;Miller;Radiat. Phys. Chem.,2003
4. Development of a 6 MeV electron beam energy Linac for fruit sterilization;Chunjarean;J. Phys.: Conf. Ser.,2023
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Design of Synchronized Pulse Signals for Bump Magnet Power Supply with FPGA-Based System;2024 8th International Conference on Robotics and Automation Sciences (ICRAS);2024-06-21