Author:
Wu W.B.,Zhou H.J.,Zhou Q.H.,Yang W.,Dong Y.,Yang W.Y.
Abstract
Abstract
Titanium hydride cathodic vacuum arc ion sources are widely
used in particle accelerators, neutron sources, etc. For the
application in neutron sources, higher H+/D+ fraction and
higher beam uniformity are preferred. In this work, to improve the
beam uniformity of a miniature titanium hydride cathodic vacuum arc
ion source, a new scheme of variable aperture extraction grids is
proposed. A 2D numerical model is developed for the investigation of
the variable aperture extraction grids. Numerical results indicate
that the extraction grid plays important roles in the titanium
hydride cathodic vacuum arc ion source that can improve the
stability of ion source. Moreover, simulated results show that the
designed variable aperture extraction grids can reduce the beam
nonuniformity to less than ±10%, while the beam nonuniformity
of the fixed aperture extraction grids are between ±22% and
±37%. Thus, the presented work can provide a potential
reference for the improvement of beam uniformity of the vacuum arc
ion sources.
Subject
Mathematical Physics,Instrumentation