A novel technique for an alignment-insensitive density calibration of Thomson scattering diagnostics developed at W7-X

Author:

Fuchert G.,Nelde P.,Pasch E.,Beurskens M.N.A.,Bozhenkov S.A.,Brunner K.J.,Meineke J.,Scott E.R.,Wolf R.C.

Abstract

Abstract In most laboratory setups in plasma physics, including magnetic-confinement experiments for fusion research, laser-based Thomson scattering allows for absolutely calibrated density measurements without input from other diagnostics and with high spatial resolution. A common issue is the alignment stability of either the laser beam or the observation optics. Frequent recalibrations are typically required. This is a challenge in particular for larger fusion experiments; while beam paths tend to get longer, the access for alignment and calibration gets more restricted. Therefore, simple, fast and robust calibration methods are required. A novel calibration technique has been developed at W7-X to account for alignment variations in the calibration procedure. This will decrease the pulse-to-pulse variations significantly and allow for a longer time duration before a recalibration becomes necessary. By monitoring the beam position accurately, it could be shown that misalignment leads to deterministic and reproducible changes in the measured density. The introduced density errors can be corrected for by monitoring the laser beam for every individual laser pulse. In the last experimental campaign, this has been done retrospectively by introducing parallel shifts to the laser beam path in order to show the feasibility of this method. It could be demonstrated that the impact of introduced shifts on the electron density can be successfully corrected for. For future campaigns, the beam alignment will intentionally be varied during the absolute calibration in order to cover the full range of expected beam positions. During the actual experiments, the beam positions will be monitored likewise and each density profile will be evaluated with the most suitable calibration factor. While probably not needed for W7-X, vibrations of the observation optics could be included in the same way.

Publisher

IOP Publishing

Subject

Mathematical Physics,Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3