Coverage factors for efficient demonstration of compliance of low-frequency magnetic near-field exposures with basic restrictions

Author:

Xi JingtianORCID,Christ Andreas,Kuster Niels

Abstract

Abstract Objective. Regulators require that wireless power transfer (WPT) systems and other strong magnetic field sources are compliant with the basic restrictions (BR) defined as the limits of the fields induced in the human body, i.e. the induced electric field/current density/specific absorption rate limits. This can be achieved by demonstrating compliance with the reference levels (RL) defined in air without the human body, i.e. the incident electric/magnetic field limits. Local sources, such as WPT transmitters, generate non-uniform fields that can locally exceed the RL while the induced fields are still well below the BR. In these cases, robust compliance with BR can be demonstrated, generally requiring a large number of simulations. In this study, we proposed an efficient evaluation using a homogeneous phantom and applying a coverage factor to account for the local field enhancements caused by the dielectric contrasts of the highly inhomogeneous human tissues. Approach. The generally applicable coverage factors were derived from a statistical analysis of the field enhancements observed on four magnetic near-field sources placed at different separation distances (2–80 mm) and locations on the back of 12 anatomical models. The field enhancements were characterized by the ratios between the peak induced fields in the anatomical models and those in the homogeneous half-space phantom (ϵ r = 55, σ = 0.75 S m−1, ρ = 1,000 kg m−3) at the same distance. Main results. The resulting 99th percentile coverage factors range from 1 and 9 depending on the dosimetric quantity. Significance. The use of these coverage factors reduces the compliance testing effort from hundreds of simulations to only one, and makes experimental testing feasible without the support of simulations. The study also demonstrates that running only a few use-case simulations with anatomical models may underestimate the exposure by more than 10 dB.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3