Evaluation of a modular all-in-one high-resolution PET detector and readout electronics setup

Author:

Schmidt F PORCID,Krämer J C,Parl C,Schmand M,Pichler B JORCID

Abstract

Abstract Objective. The all-in-one solution and modularity of the C13500 series TOF-PET detector modules (Hamamatsu Photonics K.K., Hamamatsu, Japan) make them a highly attractive candidate for the development of positron emission tomography (PET) systems. However, the commercially available portfolio targets clinical whole-body PET systems with a scintillation crystal cross area of 3.1 × 3.1 mm2. To extend the modules for high resolution (preclinical or organ specific) systems, the support for smaller scintillation crystals is required. Approach. In this work, a PET detector was developed based on the TOF-PET modules using a light sharing approach, 16 × 16 lutetium oxyorthosilicate (LSO) scintillation crystals with a size of 1.51 × 1.51 × 10.00 mm3 readout with 8 × 8 photosensor channels of size 3.0 × 3.0 mm2. In addition to hardware and software development, the optimized parameter settings for the adapted configuration were evaluated. Main Results. A factor of two in amplification of the analog signal compared to the minimum gain setting was necessary for an accurate crystal identification (peak-to-valley ratio 14.9 ± 5.9). A further increase to a factor of three was not determined as optimum as the time over threshold duration, thus pile-up probability, increased from 1032.1 ± 109.5 to 1789.5 ± 218.5 ns (photopeak position). With this amplification a full width at half maximum (FWHM) energy resolution of 14.1 ± 2.0% and a high linearity of the energy detection was obtained. A FWHM coincidence resolving time (CRT) of 313 ps was achieved by using a low timing threshold, increasing the bandwidth of the front-end circuit and using a narrow ± 1σ energy window. To approximately double the sensitivity and reduce the power consumption, the timing parameters were adjusted resulting in a FWHM CRT of 354 ps (±2σ). Significance. Based on the results obtained with the proof-of-concept detector setup, we confirm the modularity and flexibility of the all-in-one TOF-PET detector modules for the future development of application-specific high-resolution PET systems.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3