Development and evaluation of a new high-TOF-resolution all-digital brain PET system

Author:

Fang Lei,Zhang Bo,Li Bingxuan,Zhang Xiangsong,Zhou Xiaoyun,Yang Jigang,Li AngORCID,Shi Xinchong,Liu Yuqing,Kreissl Michael,D’Ascenzo NicolaORCID,Xiao Peng,Xie Qingguo

Abstract

Abstract Objective. Time-of-flight (TOF) capability and high sensitivity are essential for brain-dedicated positron emission tomography (PET) imaging, as they improve the contrast and the signal-to-noise ratio (SNR) enabling a precise localization of functional mechanisms in the different brain regions. Approach. We present a new brain PET system with transverse and axial field-of-view (FOV) of 320 mm and 255 mm, respectively. The system head is an array of 6 × 6 detection elements, each consisting of a 3.9 × 3.9 × 20 mm3 lutetium–yttrium oxyorthosilicate crystal coupled with a 3.93 × 3.93 mm2 SiPM. The SiPMs analog signals are individually digitized using the multi-voltage threshold (MVT) technology, employing a 1:1:1 coupling configuration. Main results. The brain PET system exhibits a TOF resolution of 249 ps at 5.3 kBq ml−1, an average sensitivity of 22.1 cps kBq−1, and a noise equivalent count rate (NECR) peak of 150.9 kcps at 8.36 kBq ml−1. Furthermore, the mini-Derenzo phantom study demonstrated the system’s ability to distinguish rods with a diameter of 2.0 mm. Moreover, incorporating the TOF reconstruction algorithm in an image quality phantom study optimizes the background variability, resulting in reductions ranging from 44% (37 mm) to 75% (10 mm) with comparable contrast. In the human brain imaging study, the SNR improved by a factor of 1.7 with the inclusion of TOF, increasing from 27.07 to 46.05. Time-dynamic human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 2 s per time frame. Significance. The system exhibited a good TOF capability, which is coupled with the high sensitivity and count rate performance based on the MVT digital sampling technique. The developed TOF-enabled brain PET system opens the possibility of precise kinetic brain PET imaging, towards new quantitative predictive brain diagnostics.

Funder

PNC-HLS-DA-INNOVA Platform

National Natural Science Foundation of China

National Key Research and Development Program of the Peoples Republic of China Key Program for Intergovernmental Cooperation in International Science and Technology Innovation

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3