A multichannel feature-based approach for longitudinal lung CT registration in the presence of radiation induced lung damage

Author:

Stavropoulou A,Szmul A,Chandy EORCID,Veiga C,Landau D,McClelland J RORCID

Abstract

Abstract Quantifying parenchymal tissue changes in the lungs is imperative in furthering the study of radiation induced lung damage (RILD). Registering lung images from different time-points is a key step of this process. Traditional intensity-based registration approaches fail this task due to the considerable anatomical changes that occur between timepoints. This work proposes a novel method to successfully register longitudinal pre- and post-radiotherapy (RT) lung computed tomography (CT) scans that exhibit large changes due to RILD, by extracting consistent anatomical features from CT (lung boundaries, main airways, vessels) and using these features to optimise the registrations. Pre-RT and 12 month post-RT CT pairs from fifteen lung cancer patients were used for this study, all with varying degrees of RILD, ranging from mild parenchymal change to extensive consolidation and collapse. For each CT, signed distance transforms from segmentations of the lungs and main airways were generated, and the Frangi vesselness map was calculated. These were concatenated into multi-channel images and diffeomorphic multichannel registration was performed for each image pair using NiftyReg. Traditional intensity-based registrations were also performed for comparison purposes. For the evaluation, the pre- and post-registration landmark distance was calculated for all patients, using an average of 44 manually identified landmark pairs per patient. The mean (standard deviation) distance for all datasets decreased from 15.95 (8.09) mm pre-registration to 4.56 (5.70) mm post-registration, compared to 7.90 (8.97) mm for the intensity-based registrations. Qualitative improvements in image alignment were observed for all patient datasets. For four representative subjects, registrations were performed for three additional follow-up timepoints up to 48 months post-RT and similar accuracy was achieved. We have demonstrated that our novel multichannel registration method can successfully align longitudinal scans from RILD patients in the presence of large anatomical changes such as consolidation and atelectasis, outperforming the traditional registration approach both quantitatively and through thorough visual inspection.

Funder

Royal Academy of Engineering

Cancer Research UK

National Institute for Health Research

Engineering and Physical Sciences Research Council

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference30 articles.

1. Effects of radiation therapy on the lung: radiologic appearances and differential diagnosis;Choi;Radiographics,2004

2. Comparison of two deformable registration algorithms in the presence of radiologic change between serial lung CT scans;Cunliffe;J. Digit. Imaging,2015

3. Developing clinical measures of lung function in COPD patients using medical imaging and computational modelling;Doel,2012

4. Relating radiation-induced regional lung injury to changes in pulmonary function tests;Fan;Int. J. Radiat. Oncol. Biol. Phys.,2001

5. Multiscale Vessel Enhancement Filtering;Frangi,1998

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3