Field-programable-gate-array-based distributed coincidence processor for high count-rate online positron emission tomography coincidence data acquisition

Author:

Cheng XinyiORCID,Hu Kun,Yang Dongxu,Shao Yiping

Abstract

Abstract For positron emission tomography (PET) online data acquisition, a centralized coincidence processor (CCP) with single-thread data processing has been used to select coincidence events for many PET scanners. A CCP has the advantages of highly integrated circuit, compact connection between detector front-end and system electronics and centralized control of data process and decision making. However, it also has the drawbacks of data process delay, difficulty in handling very high count-rates of single and coincidence events and complicated algorithms to implement. These problems are exacerbated when implementing a CCP on a field-programable-gate-array (FPGA) due to increased routing congestion and reduced data throughput. Industry companies have applied non-centralized or distributed data processing to solve these problems, but those solutions remain either proprietary or lack full disclosure of technical details that make the techniques unclear and difficult to adapt for most research communities. In this study, we investigated the use of a set of distributed coincidence processors (DCP) that can address the CCP problems and be implemented relatively easily. Each coincidence processor exclusively connects one detector pair and selects coincidence events from this detector pair only, which breaks a centralized coincidence process to a collection of independent and parallel processes. DCP can significantly minimize the data process delay, maximize count-rates of coincidence events and simplify implementation by implementing a single coincidence processor with one detector pair and replicating it to the rest. A prototype DCP with 42 coincidence processors was implemented on an off-the-shelf FPGA development board for a small PET with 12 detectors configured with 42 detector pairs. DCP performances were tested with both pulsed signals and gamma ray interactions. There was no coincidence data loss up to the detector’s maximum singles count-rate (250 k s−1). Approximately 1.2 k registers were utilized for each coincidence processor and the FPGA resource utilization was proportional to the number of coincidence processors. Coincidence timing spectra showed the results from accurately acquired coincidence events. In conclusion: complementary to CCP, DCP can provide high count-rate capability, with a simplified algorithm for implementation and potentially a practical solution for online acquisition of a PET with a larger number of detector pairs or for ultrahigh-throughput imaging.

Funder

National Institute of Health

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3