A carbon nanotube x-ray source array designed for a new multisource cone beam computed tomography scanner

Author:

Li Boyuan,Inscoe Christina RORCID,Xu Shuang,Capo Timothy,Tyndall Donald A,Lee Yueh Z,Lu Jianping,Zhou Otto

Abstract

Abstract Cone beam computed tomography (CBCT) is known to suffer from strong scatter and cone beam artifacts. The purpose of this study is to develop and characterize a rapidly scanning carbon nanotube (CNT) field emission x-ray source array to enable a multisource CBCT (ms-CBCT) image acquisition scheme which has been demonstrated to overcome these limitations. A CNT x-ray source array with eight evenly spaced focal spots was designed and fabricated for a medium field of view ms-CBCT for maxillofacial imaging. An external multisource collimator was used to confine the radiation from each focal spot to a narrow cone angle. For ms-CBCT imaging, the array was placed in the axial direction and rapidly scanned while rotating continuously around the object with a flat panel detector. The x-ray beam profile, temporal and spatial resolutions, energy and dose rate were characterized and evaluated for maxillofacial imaging. The CNT x-ray source array achieved a consistent focal spot size of 1.10 ± 0.04 mm × 0.84 ± 0.03 mm and individual beam cone angle of 2.4° ± 0.08 after collimation. The x-ray beams were rapidly switched with a rising and damping times of 0.21 ms and 0.19 ms, respectively. Under the designed operating condition of 110 kVp and 15 mA, a dose rate of 8245 μGy s−1 was obtained at the detector surface with the inherent Al filtration and 2312 μGy s−1 with an additional 0.3 mm Cu filter. There was negligible change of the x-ray dose rate over many operating cycles. A ms-CBCT scan of an adult head phantom was completed in 14.4 s total exposure time for the imaging dose in the range of that of a clinical CBCT scanner. A spatially distributed CNT x-ray source array was designed and fabricated. It has enabled a new multisource CBCT to overcome some of the main inherent limitations of the conventional CBCT.

Funder

University of North Carolina at Chapel Hill

National Institute of Health

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3