Intra- and inter-fraction relative range verification in heavy-ion therapy using filtered interaction vertex imaging

Author:

Hymers DevinORCID,Kasanda EvaORCID,Bildstein VinzenzORCID,Easter Joelle,Richard AndreaORCID,Spyrou ArtemisORCID,Höhr CorneliaORCID,Mücher DennisORCID

Abstract

Abstract Heavy-ion therapy, particularly using scanned (active) beam delivery, provides a precise and highly conformal dose distribution, with maximum dose deposition for each pencil beam at its endpoint (Bragg peak), and low entrance and exit dose. To take full advantage of this precision, robust range verification methods are required; these methods ensure that the Bragg peak is positioned correctly in the patient and the dose is delivered as prescribed. Relative range verification allows intra-fraction monitoring of Bragg peak spacing to ensure full coverage with each fraction, as well as inter-fraction monitoring to ensure all fractions are delivered consistently. To validate the proposed filtered interaction vertex imaging (IVI) method for relative range verification, a 16O beam was used to deliver 12 Bragg peak positions in a 40 mm poly-(methyl methacrylate) phantom. Secondary particles produced in the phantom were monitored using position-sensitive silicon detectors. Events recorded on these detectors, along with a measurement of the treatment beam axis, were used to reconstruct the sites of origin of these secondary particles in the phantom. The distal edge of the depth distribution of these reconstructed points was determined with logistic fits, and the translation in depth required to minimize the χ 2 statistic between these fits was used to compute the range shift between any two Bragg peak positions. In all cases, the range shift was determined with sub-millimeter precision, to a standard deviation of the mean of 220(10) μm. This result validates filtered IVI as a reliable relative range verification method, which should be capable of monitoring each energy step in each fraction of a scanned heavy-ion treatment plan.

Funder

Social Sciences and Humanities Research Council of Canada

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference38 articles.

1. Geant4—a simulation toolkit;Agostinelli;Nucl. Instrum. Meth. A,2003

2. Present challenges in hadrontherapy techniques;Amaldi;Eur. Phys. J. Plus,2011

3. Advanced quality assurance for CNAO;Amaldi;Nucl. Instrum. Meth. A,2010

4. Radiotherapy with beams of carbon ions;Amaldi;Rep. Prog. Phys.,2005

5. Dosimetric consequences of intrafraction prostate motion in scanned ion beam radiotherapy;Ammazzalorso;Radiother. Oncol.,2014

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献