An inception network for positron emission tomography based dose estimation in carbon ion therapy

Author:

Rutherford HarleyORCID,Saha Turai Rohan,Chacon Andrew,Franklin Daniel RORCID,Mohammadi AkramORCID,Tashima HideakiORCID,Yamaya Taiga,Parodi KatiaORCID,Rosenfeld Anatoly BORCID,Guatelli SusannaORCID,Safavi-Naeini MitraORCID

Abstract

Abstract Objective. We aim to evaluate a method for estimating 1D physical dose deposition profiles in carbon ion therapy via analysis of dynamic PET images using a deep residual learning convolutional neural network (CNN). The method is validated using Monte Carlo simulations of 12C ion spread-out Bragg peak (SOBP) profiles, and demonstrated with an experimental PET image. Approach. A set of dose deposition and positron annihilation profiles for monoenergetic 12C ion pencil beams in PMMA are first generated using Monte Carlo simulations. From these, a set of random polyenergetic dose and positron annihilation profiles are synthesised and used to train the CNN. Performance is evaluated by generating a second set of simulated 12C ion SOBP profiles (one 116 mm SOBP profile and ten 60 mm SOBP profiles), and using the trained neural network to estimate the dose profile deposited by each beam and the position of the distal edge of the SOBP. Next, the same methods are used to evaluate the network using an experimental PET image, obtained after irradiating a PMMA phantom with a 12C ion beam at QST’s Heavy Ion Medical Accelerator in Chiba facility in Chiba, Japan. The performance of the CNN is compared to that of a recently published iterative technique using the same simulated and experimental 12C SOBP profiles. Main results. The CNN estimated the simulated dose profiles with a mean relative error (MRE) of 0.7% ± 1.0% and the distal edge position with an accuracy of 0.1 mm ± 0.2 mm, and estimate the dose delivered by the experimental 12C ion beam with a MRE of 3.7%, and the distal edge with an accuracy of 1.7 mm. Significance. The CNN was able to produce estimates of the dose distribution with comparable or improved accuracy and computational efficiency compared to the iterative method and other similar PET-based direct dose quantification techniques.

Funder

Australian Government

Australian Institute of Nuclear Science and Engineering

National Computational Infrastructure

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference66 articles.

1. Geant4–a simulation toolkit;Agostinelli;Nucl. Instrum. Methods Phys. Res. A,2003

2. Deep learning for brain MRI segmentation: state of the art and future directions;Akkus;J. Digital Imaging,2017

3. Construction and validation of a low cost paediatric pelvis phantom;Ali;Eur. J. Radiol.,2018

4. A Review of the properties and applications of poly (Methyl Methacrylate) (PMMA);Ali;Polym. Rev.,2015

5. Recent developments in Geant4;Allison;Nucl. Instrum. Methods Phys. Res. A,2016

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3