Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication

Author:

Ji Xu,Treb Kevin,Li KeORCID

Abstract

Abstract This work reports an edge enhancing effect experimentally observed in cadmium telluride (CdTe)-based photon counting detector (PCD) systems operated under the charge summing (CS) mode and irradiated by high-flux x-rays. Experimental measurements of the edge spread functions (ESFs) of a PCD system (100 μm pixel size, 88 ns deadtime) were performed at different input flux levels from 4.5 × 105 count per second (cps) mm−2 to 1.5 × 109 cps mm−2 for the single pixel mode (SP) and the CS mode. A theoretical model that incorporates the impacts of inter-pixel communications and the arbitration process involved in the CS mode was developed to help explain the physical origin of the observed edge enhancing effect. Compared with the monotonically increasing ESF of the SP mode, the ESF of the CS mode measured at high-flux levels shows a peak at an intermediate location (50 μm from the edge). The peak became more pronounced with increasing flux levels. The theoretically calculated ESFs agreed well with experimental results with relative errors less than 5% at all flux levels and tested. These results indicate that the anomalous edge enhancing effect is jointly caused by the pileup effect and the CS circuit that introduces negative correlations between adjacent pixels. When the input flux is high enough to deliver photons to multiple adjacent pixels within the same deadtime period, the CS mode may treat the coincident x-rays as shared charges and thus introduce count losses in addition to the well-known pileup count loss. When a high contrast object partially blocks certain pixels from x-rays, the adjacent unblocked pixels have an increased probability of registering counts as a result of the negative correlation. This leads to a peak on the ESF at a pixel-to-edge distance half of the pixel pitch.

Funder

National Institute of Biomedical Imaging and Bioengineering

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3