A framework for prediction of personalized pediatric nuclear medical dosimetry based on machine learning and Monte Carlo techniques

Author:

Eleftheriadis VasileiosORCID,Savvidis GeorgiosORCID,Paneta ValentinaORCID,Chatzipapas KonstantinosORCID,Kagadis George CORCID,Papadimitroulas PanagiotisORCID

Abstract

Abstract Objective: A methodology is introduced for the development of an internal dosimetry prediction toolkit for nuclear medical pediatric applications. The proposed study exploits Artificial Intelligence techniques using Monte Carlo simulations as ground truth for accurate prediction of absorbed doses per organ prior to the imaging acquisition considering only personalized anatomical characteristics of any new pediatric patient. Approach: GATE Monte Carlo simulations were performed using a population of computational pediatric models to calculate the specific absorbed dose rates (SADRs) in several organs. A simulated dosimetry database was developed for 28 pediatric phantoms (age range 2–17 years old, both genders) and 5 different radiopharmaceuticals. Machine Learning regression models were trained on the produced simulated dataset, with leave one out cross validation for the prediction model evaluation. Hyperparameter optimization and ensemble learning techniques for a variation of input features were applied for achieving the best predictive power, leading to the development of a SADR prediction toolkit for any new pediatric patient for the studied organs and radiopharmaceuticals. Main results. SADR values for 30 organs of interest were calculated via Monte Carlo simulations for 28 pediatric phantoms for the cases of five radiopharmaceuticals. The relative percentage uncertainty in the extracted dose values per organ was lower than 2.7%. An internal dosimetry prediction toolkit which can accurately predict SADRs in 30 organs for five different radiopharmaceuticals, with mean absolute percentage error on the level of 8% was developed, with specific focus on pediatric patients, by using Machine Learning regression algorithms, Single or Multiple organ training and Artificial Intelligence ensemble techniques. Significance: A large simulated dosimetry database was developed and utilized for the training of Machine Learning models. The developed predictive models provide very fast results (<2 s) with an accuracy >90% with respect to the ground truth of Monte Carlo, considering personalized anatomical characteristics and the biodistribution of each radiopharmaceutical. The proposed method is applicable to other medical dosimetry applications in different patients’ populations.

Funder

European High-Performance Computing Joint Undertaking (JU) through the FF4EuroHPC

Hellenic Foundation for Research and Innovation

CHIST-ERA

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference46 articles.

1. Radiation risk in nuclear medicine;Adelstein;Semin. Nucl. Med.,2014

2. Geant4 a simulation toolkit;Agostinelli;Nucl. Instrum. Meth. A,2003

3. An update on computational anthropomorphic anatomical models;Akhavanallaf;Digit Health.,2022

4. Whole-body voxel-based internal dosimetry using deep learning;Akhavanallaf;Eur. J. Nucl. Med. Mol. Imaging,2021

5. Recent developments in Geant4;Allison;Nucl. Instrum. Meth. A,2016

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3