Design of a generic method for single dual-tracer PET imaging acquisition in clinical routine

Author:

Taheri NasrinORCID,Le Crom Benjamin,Bouillot Caroline,Chérel Michel,Costes NicolasORCID,Gouard Sébastien,Marionneau-Lambot Séverine,Merlin Thibault,Visvikis Dimitris,Stute Simon,Carlier Thomas

Abstract

Abstract Using different tracers in positron emission tomography (PET) imaging can bring complementary information on tumor heterogeneities. Ideally, PET images of different tracers should be acquired simultaneously to avoid the bias induced by movement and physiological changes between sequential acquisitions. Previous studies have demonstrated the feasibility of recovering separated PET signals or parameters of two or more tracers injected (quasi-)simultaneously in a single acquisition. In this study, a generic framework in the context of dual-tracer PET acquisition is proposed where no strong kinetic assumptions nor specific tuning of parameters are required. The performances of the framework were assessed through simulations involving the combination of [18F]FCH and [18F]FDG injections, two protocols (90 and 60 min acquisition durations) and various activity ratios between the two injections. Preclinical experiments with the same radiotracers were also conducted. Results demonstrate the ability of the method both to extract separated arterial input functions (AIF) from noisy image-derived input function and to separate the dynamic signals and further estimate kinetic parameters. The compromise between bias and variance associated with the estimation of net influx rate K i shows that it is preferable to use the second injected radiotracer with twice the activity of the first for both 90 min [18F]FCH+[18F]FDG and 60 min [18F]FDG+[18F]FCH protocols. In these optimal settings, the weighted mean-squared-error of the estimated AIF was always less than 7%. The K i bias was similar to the one of single-tracer acquisitions; below 5%. Compared to single-tracer results, the variance of K i was twice more for 90 min dual-tracer scenario and four times more for the 60 min scenario. The generic design of the method makes it easy to use for other pairs of radiotracers and even for more than two tracers. The absence of strong kinetic assumptions and tuning parameters makes it suitable for a possible use in clinical routine.

Funder

SIRIC ILIAD

NExT Junior Talent project TRAC

France Life Imaging

RHU OPERANDI

Labex IRON

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3