Built-in wavelet-induced smoothness to reduce plan complexity in intensity modulated radiation therapy (IMRT)

Author:

Tefagh MojtabaORCID,Zarepisheh MasoudORCID

Abstract

Abstract Objective. Reducing plan complexity in intensity modulated radiation therapy (IMRT) to ensure dosimetric accuracy and delivery efficiency of the radiation treatment plans. We propose a novel approach by representing the beamlet intensities using an incomplete wavelet basis that explicitly excludes fluctuating intensity maps from the decision space (explicit hard constraint). This technique provides a built-in wavelet-induced smoothness that improves both dosimetric plan quality and delivery efficiency. Approach. The beamlet intensity maps need to be especially smooth in the leaf travel direction (referred to as the X-direction). We treat the intensity map of each beam as a 2D image and represent it using the wavelets corresponding to low-frequency changes in the X-direction (i.e. approximation and horizontal). The absence of wavelets corresponding to high-frequency changes (i.e. vertical and diagonal) induces built-in smoothness. We still utilize a regularization term in the objective function to promote smoothness in the Y-direction (perpendicular to the X-direction) and further possible smoothness in the X-direction. This technique has been tested on three patient cases of different disease sites (paraspinal, lung, prostate) and all final evaluations and comparisons have been performed on an FDA-approved commercial treatment planning system (Varian EclipseTM). Main results. Wavelet-induced smoothness reduced monitor units by about 10%, 45%, and 14% for paraspinal, lung, and prostate cases, respectively. It also improved organ at risk sparing, especially on the complex paraspinal case where it resulted in about 7%, 13%, and 14% less mean dose to esophagus, lung, and cord, respectively. Moreover, built-in wavelet-induced smoothness desensitizes the results to changing the weight associated to the regularization term, and thereby mitigates the weight fine-tuning difficulty. Significance. Fluence smoothness is often achieved by smoothing the beamlet intensity maps using a proper regularization term in the objective function aiming at disincentivizing fluctuation in the beamlet intensities (implicit soft constraint). This work reports a novel application of wavelets in imposing an explicit smoothness hard constraint in the search space using an incomplete wavelet basis. This idea has been successfully applied to exclude complex and clinically irrelevant radiation plans from the search space. The code and pertained models along with a sample dataset are released on our LowDimRT GitHub (https://github.com/PortPy-Project/LowDimRT).

Funder

Center for Strategic Scientific Initiatives, National Cancer Institute

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3