Cost-function testing methodology for image-based registration of endoscopy to CT images in the head and neck

Author:

Shi Runjie BORCID,Mirza Souzan,Martinez Diego,Douglas Catriona,Cho John,Irish Jonathon C,Jaffray David AORCID,Weersink Robert AORCID

Abstract

Abstract One of the largest geometric uncertainties in designing radiotherapy treatment plans for squamous cell cancers of the head and neck is contouring the gross tumor volume. We have previously described a method of projecting mucosal disease contours, visible on endoscopy, to volumetrically reconstructed planning computed tomography (CT) datasets, using electromagnetic (EM) tracking of a flexible endoscope, enabling rigid registration between endoscopic and CT images. However, to achieve better accuracy for radiotherapy planning, we propose refining this initial registration with image-based registration methods. In this paper, several types of cost functions are evaluated based on accuracy and robustness. Three phantoms and eight clinical cases are used to test each cost function, with initial registration of endoscopy to CT provided by the pose of the flexible endoscope recovered from EM tracking. Cost function classes include: cross correlation, mutual information and gradient methods. For each test case, a ground truth virtual camera pose was first defined by manual registration of anatomical features visible in both real and virtual endoscope images. A new set of evenly spaced fiducial points and a sample contour were created and projected onto the CT image to be used in assessing image registration quality. A new set of 5000 displaced poses was generated by random sampling displacements along each translational and rotational dimension. At each pose, fiducial and contour points in the real image were again projected on the CT image. The cost function, fiducial registration error and contouring error values were then calculated. While all cost functions performed well in select cases, only the normalized gradient field function consistently had registration errors less than 2 mm, which is the accuracy needed if this application of registering mucosal disease identified on optical image to CT images is to be used in the clinical practice of radiation treatment planning. (Registration: ClinicalTrials.gov NCT02704169)

Funder

Canadian Institutes of Health Research

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference27 articles.

1. Image-guided interventions: technology review and clinical applications;Cleary;Annu. Rev. Biomed. Eng.,2010

2. Fusion of intraoperative cone-beam CT and endoscopic video for image-guided procedures;Daly,2010

3. Selective image similarity measure for bronchoscope tracking based on image registration;Deguchi;Med. Image Anal.,2009

4. Pattern Classification and Scene Analysis;Duda,1973

5. Image matching by normalized cross-correlation;Feng,2006

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3