A practical and robust method for beam blocker-based cone beam CT scatter correction

Author:

Cui Hehe,Jiang Xiao,Tang Wei,Lu Hsiao-Ming,Yang Yidong

Abstract

Abstract Objective. In the traditional beam-blocker based cone beam CT (CBCT) scatter correction, the scatter measured in the region shaded by lead strips was multiplied by a correction factor to directly represent the scatter in the unblocked region. The correction factor optimization is a tedious process and lacks an objective stop criterion. To skip the optimization process, an indirect scatter estimation method was developed and validated in phantom imaging. Approach. A beam-blocker made of lead strips was mounted between the x-ray source and object for scatter estimation. The primary signal between lead strips in the blocked region was first calculated by subtracting the measured scatter, and then used to calculate the scatter signal in the unblocked region corresponding to the same attenuation path. The calculated scatter signal was smoothed via local filtration and used to correct the measured projection in the unblocked region. Finally, the CBCT was reconstructed via Feldkamp–Davis–Kress algorithm. A Catphan and a head phantom were used to verify the performance of the proposed method in both full- and half-blocker scenarios, and with and without a bow-tie filter. Main Results. For scans without the bow-tie filter, the CT number error was reduced to 3.97 ± 2.27 and 5.51 ± 3.90 HU in the full- and half-blocker scenarios, respectively, for the Catphan, and to 4.01 ± 2.18 and 7.97 ± 4.05 HU for the head phantom. When the bow-tie filter was applied, the CT number error was reduced to 2.29 ± 1.42 and 6.72 ± 0.77 HU in the full- and half-blocker scenarios, respectively, for the Catphan, and 2.35 ± 1.25 and 4.96 ± 1.89 HU for the head phantom. Significance. The proposed method effectively avoids the influence of the inserted beam blocker itself on the scatter intensity estimation, and proves a more practical and robust way for the beam-blocker based scatter correction in CBCT scanning.

Funder

the Fundamental Research Funds for the Central Universities

Anhui Provincial-level S&T Megaprojects

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3