Energy and electron drift time measurements in a pixel CCI TlBr detector with 1.3 MeV prompt-gammas

Author:

Ariño-Estrada GerardORCID,Kim Hadong,Du JunweiORCID,Cirignano Leonard J,Shah Kanai S,Cherry Simon RORCID

Abstract

Abstract Assessing the position of the Bragg peak (BP) in hadron radiotherapy utilizing prompt-gamma imaging (PGI) presents many challenges in terms of detector physics. Gamma detectors with the capability of extracting the best energy, timing, and spatial information from each gamma interaction, as well as with high detection efficiency and count rate performance, are needed for this application. In this work we present the characterization of a pixel Čerenkov charge induction (CCI) thallium bromide (TlBr) detector in terms of energy and and electron drift time for its potential use in PGI. The CCI TlBr detector had dimensions of 4 × 4 × 5 mm3 and one of its electrodes was segmented in pixels with 1.7 mm pitch. A silicon photomultiplier (SiPM) was optically coupled to one of the faces of the TlBr slab to read out the Čerenkov light promptly emitted after the interaction of a gamma ray. The detector was operated stand-alone and the 1.275 prompt gammas from a 22Na radioactive source were used for the study. The electron drift time was obtained by combining the Čerenkov and charge induction signals and then used as a measure of the depth of interaction. The electron mobility in TlBr was estimated as ∼27 cm2 V−1 s−1. Energy resolutions between 3.4% and 4.0% at 1.275 MeV were obtained after depth-correction. These values improved to 3.0%–3.3% when events with drift times of 3–6 μs were selected. These results show the potential of pixel CCI TlBr detectors to resolve gamma interactions in the detector with mm-like accuracy in 3D and with excellent energy resolution. Previous studies with CCI TlBr devices have shown a timing resolution of <400 ps full width at half maximum when detecting 511 keV gamma rays, therefore, the timing accuracy is expected to improve with the increased energy of the gamma rays in PGI. While other important detector characteristics such as count rate capability remain to be studied, results from this work combined with other preliminary data show pixel CCI detectors can simultaneously provide excellent energy, timing, and spatial resolution performance and are a very promising option for PGI in hadron therapy.

Funder

National Cancer Institute

National Institute of Biomedical Imaging and Bioengineering

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference17 articles.

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Feasibility study of CdMnTeSe based diagnostic X-ray detector;Nuclear Engineering and Technology;2024-06

2. Prompt gamma timing for proton range verification with TlBr and TlCl as pure Cherenkov emitters;Physics in Medicine & Biology;2024-05-14

3. Cherenkov Light Emission in Pure Cherenkov Emitters for Prompt Gamma Imaging;IEEE Transactions on Radiation and Plasma Medical Sciences;2024-01

4. Reversible capacitive Frisch grid TlBr detectors;Japanese Journal of Applied Physics;2023-09-01

5. Characterization of coincidence time resolutions of TlBr x Cl1−x crystals as Cherenkov radiators;Japanese Journal of Applied Physics;2023-08-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3