Resolving inter-crystal scatter in a light-sharing depth-encoding PET detector

Author:

Petersen EricORCID,LaBella Andy,Li Yixin,Wang Zipai,Goldan Amir H

Abstract

Abstract Objective. Inter-crystal scattering (ICS) in light-sharing positron emission tomography (PET) detectors leads to ambiguity in positioning the initial interaction, which significantly degrades the contrast, quantitative accuracy, and spatial resolution of the resulting image. Here, we attempt to resolve the positioning ambiguity of ICS in a light-sharing depth-encoding detector by exploiting the confined, deterministic light-sharing enabled by the segmented light guide unique to Prism-PET. Approach. We first considered a test case of ICS between two adjacent crystals using an analytical and a neural network approach. The analytical approach used a Bayesian estimation framework constructed from a scatter absorption model—the prior—and a detector response model—the likelihood. A simple neural network was generated for the same scenario, to provide mutual validation for the findings. Finally, we generalized the solution to three-dimensional event positioning that handles all events in the photopeak using a convolutional neural network with unique architecture that separately predicts the identity and depth-of-interaction (DOI) of the crystal containing the first interaction. Main results. The analytical Bayesian method generated an estimation error of 20.5 keV in energy and 3.1 mm in DOI. Further analysis showed that the detector response model was sufficiently robust to achieve adequate performance via maximum likelihood estimation (MLE), without prior information. We then found convergent results using a simple neural network. In the generalized solution using a convolutional neural network, we found crystal identification accuracy of 83% and DOI estimation error of 3.0 mm across all events. Applying this positioning algorithm to simulated data, we demonstrated significant improvements in image quality over the baseline, centroid-based positioning approach, attaining 38.9% improvement in intrinsic spatial resolution and enhanced clarity in hot spots of diameters 0.8 to 2.5 mm. Significance. The accuracy of our findings exceeds those of previous reports in the literature. The Prism-PET light guide, mediating confined and deterministic light-sharing, plays a key role in ICS recovery, as its mathematical embodiment—the detector response model—was the essential driver of accuracy in our results.

Funder

National Institutes of Health

Publisher

IOP Publishing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3