Comprehensive data set to include interference effects in Monte Carlo models of x-ray coherent scattering inside biological tissues

Author:

Paternò GORCID,Cardarelli PORCID,Gambaccini M,Taibi AORCID

Abstract

Abstract Interference effects are included in the x-ray coherent scattering models used in Monte Carlo codes by modifying each material form factor through a proper interference function, which is obtained directly from the measured scattering pattern. This approach is effective for non-biological materials, but it is impractical for biological tissues, due the wide composition variability they can feature. Instead, a given biological sample can be considered as a proper mixture of four basis materials: fat, water, collagen and calcium hydroxyapatite. The sample form factor can then be obtained through a weighted mean of the form factors of the basis materials, which include interference effects. Here, we fully demonstrate the validity of the proposed segmentation method by applying it to 31 biological tissue samples whose form factors are available in the literature. The segmentation, namely the determination of the optimal weight of the basis components, was carried out through a multiple linear regression or, in some cases, by using a controlled trial and error sequence. The form factors of the basis materials were extracted from previous works and elaborated to include more scattering features. In particular, they were interpolated at a denser grid. Furthermore, the data measured separately in wide angle and small angle regimes, for fat and collagen, were merged. In general, a very good agreement was obtained between the original sample and the calculated mixture, being the mean relative difference of their scattering profiles and their attenuation coefficients ∼10%. The segmentation method is fully supported by our extension to the Geant4 model of x-ray coherent scattering, which was used to compare simulated scatter distributions with known experimental data. The developed Geant4 code and a series of molecular form factors, including those of the basis materials, are freely downloadable from a dedicated web repository.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference102 articles.

1. Geant4 - a simulation toolkit;Agostinelli;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2003

2. Minimum detectable limits of measuring bone mineral density using an energy dispersive x-ray diffraction system;Allday;Radiat. Phys. Chem.,2001

3. Recent developments in geant4;Allisom;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2016

4. Validation and verification of geant4 standard electromagnetic physics;Apostolakis,2010

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3