Optimization of solid tank design for fan-beam optical CT based 3D radiation dosimetry

Author:

Ogilvy A,Collins S,Tuokko T,Hilts M,Deardon R,Hare W,Jirasek AORCID

Abstract

Abstract Optical computed tomography (CT) is one of the leading modalities for imaging gel dosimeters for 3D radiation dosimetry. There exist multiple scanner designs that have showcased excellent 3D dose verification capabilities of optical CT gel dosimetry. However, due to multiple experimental and reconstruction based factors there is currently no single scanner that has become a preferred standard. A significant challenge with setup and maintenance can be attributed to maintaining a large refractive index bath (1–15 l). In this work, a prototype solid ‘tank’ optical CT scanner is proposed that minimizes the volume of refractive index bath to between 10 and 35 ml. A ray-path simulator was created to optimize the design such that the solid tank geometry maximizes light collection across the detector array, maximizes the volume of the dosimeter scanned, and maximizes the collected signal dynamic range. An objective function was created to score possible geometries, and was optimized to find a local maximum geometry score from a set of possible design parameters. The design parameters optimized include the block length x bl , bore position x bc , fan-laser position x lp , lens block face semi-major axis length x ma , and the lens block face eccentricity x be . For the proposed design it was found that each of these parameters can have a significant effect on the signal collection efficacy within the scanner. Simulations scores are specific to the attenuation characteristics and refractive index of a simulated dosimeter. It was found that for a FlexyDos3D dosimeter, the ideal values for each of the five variables were: x bl = 314 mm, x bc = 6.5 mm, x lp = 50 mm, x ma = 66 mm, and x be = 0. In addition, a ClearView dosimeter was found to have ideal values at: x bl = 204 mm, x bc = 13 mm, x lp = 58 mm, x ma = 69 mm, and x be = 0. The ray simulator can also be used for further design and testing of new, unique and purpose-built optical CT geometries.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3