Bioimpedance analysis as a tool for hemodynamic monitoring: overview, methods and challenges

Author:

Anand GautamORCID,Yu Yang,Lowe Andrew,Kalra AnubhaORCID

Abstract

Abstract Recent advances in hemodynamic monitoring have seen the advent of non-invasive methods which offer ease of application and improve patient comfort. Bioimpedance Analysis or BIA is one of the currently employed non-invasive techniques for hemodynamic monitoring. Impedance Cardiography (ICG), one of the implementations of BIA, is widely used as a non-invasive procedure for estimating hemodynamic parameters such as stroke volume (SV) and cardiac output (CO). Even though BIA is not a new diagnostic technique, it has failed to gain consensus as a reliable measure of hemodynamic parameters. Several devices have emerged for estimating CO using ICG which are based on evolving methodologies and techniques to calculate SV. However, the calculations are generally dependent on the electrode configurations (whole body, segmental or localised) as well as the accuracy of different techniques in tracking blood flow changes. Blood volume changes, concentration of red blood cells, pulsatile velocity profile and ambient temperature contribute to the overall conductivity of blood and hence its impedance response during flow. There is a growing interest in investigating limbs for localised BIA to estimate hemodynamic parameters such as pulse wave velocity. As such, this paper summarises the current state of hemodynamic monitoring through BIA in terms of different configurations and devices in the market. The conductivity of blood flow has been emphasized with contributions from both volume and velocity changes during flow. Recommendations for using BIA in hemodynamic monitoring have been mentioned highlighting the suitable range of frequencies (1 kHz–1 MHz) as well as safety considerations for a BIA setup. Finally, current challenges in using BIA such as geometry assumption and inaccuracies have been discussed while mentioning potential advantages of a multi-frequency analysis to cover all the major contributors to blood’s impedance response during flow.

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

Reference276 articles.

1. Diagnosis of arterial thrombosis and stenosis in blood vessel using bioimpedance analysis;Abdessalem;Int. Res. J. Eng. Tech.,2015

2. Prospective evaluation of cardiac decompensation in patients with heart failure by Impedance Cardiography Test: the PREDICT MulticenterTrial;Abraham;Circulation,2004

3. Impedance cardiography and quantitative tissue Doppler echocardiography for evaluating the effect of cardiac resynchronization therapy: a case report;Adachi;J. Cardiol.,2003

4. Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit;Alhashemi;Curr. Heart Fail. Rep.,2010

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3