Wearable pulmonary monitoring system with integrated functional lung imaging and chest sound recording: a clinical investigation in healthy subjects

Author:

Frerichs IORCID,Paradiso RORCID,Kilintzis V,Rocha B MORCID,Braun FORCID,Rapin M,Caldani L,Beredimas N,Trechlis R,Suursalu SORCID,Strodthoff CORCID,Pessoa DORCID,Chételat O,Paiva R PORCID,de Carvalho PORCID,Maglaveras N,Weiler N,Wacker JORCID

Abstract

Abstract Objective. Current wearable respiratory monitoring devices provide a basic assessment of the breathing pattern of the examined subjects. More complex monitoring is needed for healthcare applications in patients with lung diseases. A multi-sensor vest allowing continuous lung imaging by electrical impedance tomography (EIT) and auscultation at six chest locations was developed for such advanced application. The aims of our study were to determine the vest’s capacity to record the intended bio-signals, its safety and the comfort of wearing in a first clinical investigation in healthy adult subjects. Approach. Twenty subjects (age range: 23–65 years) were studied while wearing the vests during a 14-step study protocol comprising phases of quiet and deep breathing, slow and forced full expiration manoeuvres, coughing, breath-holding in seated and three horizontal postures. EIT, chest sound and accelerometer signals were streamed to a tablet using a dedicated application and uploaded to a back-end server. The subjects filled in a questionnaire on the vest properties using a Likert scale. Main results. All subjects completed the full protocol. Good to excellent EIT waveforms and functional EIT images were obtained in 89% of the subjects. Breathing pattern and posture dependent changes in ventilation distribution were properly detected by EIT. Chest sounds were recorded in all subjects. Detection of audible heart sounds was feasible in 44%–67% of the subjects, depending on the sensor location. Accelerometry correctly identified the posture in all subjects. The vests were safe and their properties positively rated, thermal and tactile properties achieved the highest scores. Significance. The functionality and safety of the studied wearable multi-sensor vest and the high level of its acceptance by the study participants were confirmed. Availability of personalized vests might further advance its performance by improving the sensor-skin contact.

Funder

European Commission

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3