Regional lung function measures determined by electrical impedance tomography during repetitive ventilation manoeuvres in patients with COPD

Author:

Lasarow L,Vogt B,Zhao ZORCID,Balke L,Weiler N,Frerichs IORCID

Abstract

Abstract Objective. Current standards for conducting spirometry examinations recommend that the ventilation manoeuvres needed in pulmonary function testing are carried out repeatedly during sessions. Chest electrical impedance tomography (EIT) can determine the presence of ventilation heterogeneity during such manoeuvres, which increases the information content derived from such examinations. The aim of this study was to characterise regional lung function in patients with chronic obstructive pulmonary disease (COPD) during repetitive forced full ventilation manoeuvres. Regional lung function measures derived from these manoeuvres were compared with quiet tidal breathing. Approach. Sixty hospitalised patients were examined during up to three repeated ventilation manoeuvres. Acceptable spirometry manoeuvres were performed and EIT recordings suitable for analysis obtained in 53 patients (12 women, 41 men; age: 68 ± 12 years (mean ± SD)). Pixel values of tidal volume, forced full inspiratory and expiratory volume in 1 s, and forced inspiratory and expiratory vital capacity were calculated from the EIT data. Spatial ventilation heterogeneity was assessed using the coefficient of variation, global inhomogeneity index, and centres and regional fractions of ventilation. Temporal inhomogeneity was determined by examining the pixel expiration times needed to exhale 50% and 75% of regional forced vital capacity. Main results. All EIT-derived measures of regional lung function showed reproducible results during repetitive examinations. Parameters of spatial heterogeneity obtained from quiet tidal breathing were comparable with the measures derived from the forced manoeuvres. Significance. Measures of spatial and temporal ventilation heterogeneity obtained in COPD patients by EIT provide comparable findings during repeated examinations within one testing session. Quiet tidal breathing generates similar information on ventilation heterogeneity as forced manoeuvres that demand a high amount of patient effort.

Funder

European Commission

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3