Abstract
Abstract
In order to improve the machining efficiency and the surface quality of EDM/ECM, adding a small amount of sodium nitrate into deionized water as the working medium, a novel simultaneous machining approach of EDM and ECM (SEDCM) was developed. In this work, a comparative study was conducted on the SEDCM performance of TC4 alloy using different electrode materials viz. brass, copper and copper-tungsten alloy. In addition, the effects of process parameters, such as peak current, pulse on time and gap voltage on material removal rate (MRR), tool wear rate (TWR), surface roughness (Ra), and surface micromorphology were investigated. The results show that brass electrode provides the smallest MRR, the highest TWR and the worst surface quality. The copper electrode has the smallest average diameter of a single discharge craters and the best surface finish. The MRR and TWR of copper-tungsten electrode are similar to those of copper electrode. As peak current increases, TWR increases and Ra deteriorates for all the electrodes, as well MRR increases and then decreases for copper and copper-tungsten electrodes. Increase in pulse on time and gap voltage, MRR and TWR increases and then decreases gradually. At higher pulse on time and gap voltage, Ra becomes greater for three type electrodes.
Funder
Natural Science Foundation of Shandong Province
the Open Research Fund Program of Shandong Provincial Key Laboratory of Precision Manufacturing and Non-traditional Machining
Subject
Materials Chemistry,Surfaces, Coatings and Films,Process Chemistry and Technology,Instrumentation
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献