Effect of the electric field profile on the accuracy of E-FISH measurements in ionization waves

Author:

Chng Tat LoonORCID,Pai David ZORCID,Guaitella OlivierORCID,Starikovskaia Svetlana MORCID,Bourdon AnneORCID

Abstract

Abstract Electric field induced second harmonic (E-FISH) generation has emerged as a versatile tool for measuring absolute electric field strengths in time-varying, non-equilibrium plasmas and gas discharges. Yet recent work has demonstrated that the E-FISH signal, when produced with tightly focused laser beams, exhibits a strong dependence on both the length and shape of the applied electric field profile (along the axis of laser beam propagation). In this paper, we examine the effect of this dependence more meaningfully, by predicting what an E-FISH experiment would measure in a plasma, using 2D axisymmetric numerical fluid simulations as the true value. A pin-plane nanosecond discharge at atmospheric pressure is adopted as the test configuration, and the electric field evolution during the propagation of the ionization wave (IW) is specifically analysed. We find that the various phases of this evolution (before and up to the front arrival, immediately behind the front and after the connection to the grounded plane) are quite accurately described by three unique electric field profile shapes, each of which produces a different response in the E-FISH signal. As a result, the accuracy of an E-FISH measurement is generally predicted to be comparable in the first and third phases of the IW evolution, and significantly poorer in the second (intermediate) phase. Fortunately, even though the absolute error in the field strength at certain time instants could be large, the overall shape of the field evolution curve is relatively well captured by E-FISH. Guided by the simulation results, we propose a procedure for estimating the error in the initial phase of the IW development, based on the presumption that the starting field profile mirrors that of its corresponding Laplacian conditions before evolving further. We expect that this approach may be readily generalized and applicable to other IW problems or phenomena, thus extending the utility of the E-FISH diagnostic.

Funder

French General Directorate of Armaments

French–Russian international Research Project

French National Research Agency

Publisher

IOP Publishing

Subject

Condensed Matter Physics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3