Abstract
Abstract
Porous microneedle electrodes with pores of ∼1 µm diameter were fabricated by electroless plating of nickel followed by gold on a polymer monolith of poly(glycidyl methacrylate). The specific surface area of the fabricated electrode evaluated by the Brunauer–Emmett–Teller method was 2.559 ± 0.050 m2 g−1 (standard error of mean), while that of the non-porous control was <0.001 m2 g−1. Electrochemical glucose sensors were then fabricated by immobilizing glucose oxidase on the gold-plated microneedle electrodes. The sensitivity of the porous microneedle glucose sensor between 0 and 15 mM glucose was 22.99 ± 0.72 µA mM−1, and that of the non-porous control was 3.16 ± 0.56 µA mM−1. The amperometry of glucose concentration in solution was demonstrated using the fabricated electrode as a working electrode, along with an Ag/AgCl reference electrode and gold counter electrode both of which were made of microneedles. These results indicate the advantages of porous structures for electrochemical sensing with increased sensitivity.
Funder
AIMR Fusion Research
Tohoku University Research Institutes’ Ensemble Grant for Young Researchers
Japan Society for the Promotion of Science
Tanaka Kikinzoku Memorial Foundation
Center of Innovation Program
Subject
Materials Chemistry,General Energy,Materials Science (miscellaneous)
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献