Author:
Li Biqing,Li Jinbao,Xu Wenping
Abstract
Abstract
In this paper, based on a 30-story building with frame-core tube structure system, three comparative schemes are established of reinforced concrete core tube construction, steel-reinforced concrete core tube construction and the combined shear wall core tube structure with the grid-tube-type double steel plate wall with infilled concrete are established, and the dynamic elastoplastic time history is analyzed. Research shows that under the influence of a severe earthquake, the lateral strength degradation and stiffness degradation are slow on the Joint structural system of concrete filled steel tubular frame and composite shear wall core tube structure with the grid-tube-type double steel plate wall with infilled concrete, so interlayer shear force and bottom shear force increase, structural lateral stiffness increased significantly, interlayer displacement angle reduces significantly, and it improves the seismic performance of tall building.
Reference13 articles.
1. Structural design of the Shanghai Tower for wind loads [J];Zhao;Journal of Building Structures,2011
2. Structural design of Shanghai World Financial Center [J];Wang;Building Structure,2007
3. Experimental and theoretical behavior of double skin composite walls under in-plane shear[J];Hossain;Journal of Constructional Steel research,2004
4. Behavior of double skin composite wall subjected to in-plane cyclic loading [J];Eom;Journal of Structural Engineering, ASCE,2009
5. Current situation and discussion of structural design for super high-rise buildings above 250m in China[J];Ding;Journal of Building Structures,2014
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献