Abstract
Abstract
An extensive analysis of the global energy balance on the ASDEX Upgrade (AUG) tokamak has been performed. For such a purpose a complete revamping of the AUG cooling water calorimetry originally described in (Richter and Vernickel 1994 Rev. Sci. Instrum.
65 5) has been done. The system, which has been largely improved, consists of 88 cooling units, which provides an almost perfect toroidal and poloidal coverage of the in-vessel components of the AUG tokamak. To measure the energy loss due to radiation, which is only partially captured by the cooling water calorimetry, a novel framework is introduced to calculate the losses utilizing bolometric data. The analysis of the global energy balance based on almost 600 discharges reveal the remarkable capability to account more than 95% of the total injected energy on average.
Funder
Euratom Research and Training Programme
Subject
Condensed Matter Physics,Nuclear Energy and Engineering
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献