A simple and precise calibration method for binocular vision

Author:

Zimiao ZhangORCID,Kai Xu,Yanan WuORCID,Shihai Zhang,Yang Qi

Abstract

Abstract Binocular vision is an important part of machine vision measurement. Calibration accuracy is crucial for binocular vision. As for the determination of the structure parameters of the two cameras, the existing approaches usually obtain the initial values and optimize them according to the image-space errors, object-space errors or a combination of these. In the optimization process, constructing the objective function only through the image-space errors or object-space errors is not enough. Moreover, the image-space and object-space errors can form a variety of combinations to construct the objective function. Therefore, it is hard to choose the error criterion. An inadequate error criterion may lead to over-optimized or local minima (ambiguity solution). To solve this problem, this paper proposes a simple and precise calibration method for binocular vision based on the points distance constraints and image-space errors. The process of determining the structure parameters was divided into noniterative and iterative parts. We calculated the structure parameters of the two cameras according to the distance constraints of every two feature points noniteratively. The results obtained in this step were set as the initial value and refined through minimizing the reprojection errors using the Levenberg–Marquardt method. Because the results obtained in the noniterative step are accurate enough, only one iteration is needed. In this way, we finish the calibration avoiding the need to choose the error criterion. Furthermore, our method reduces the number of iterations to improve the calibration efficiency on the premise of guaranteeing the calibration accuracy. The experimental results show the superiority of this calibration method compared with other calibration methods. Using the calibration results of our method, in the measurement range of −45°∼ 45°, the rotation angle measurement error was less than ±0.032°. In the measurement range of 0 ∼ 39 mm, the displacement measurement error was less than ±0.047 mm. As for the length measurement of a 300 × 225 mm target, the length measurement error was less than ±0.039 mm.

Funder

Science and Technology Foundation of Tianjin Eye Hospital

Natural Science Foundation of Tianjin

Tianjin Health science and Technology Project

National Natural Science Foundation of China

Publisher

IOP Publishing

Subject

Applied Mathematics,Instrumentation,Engineering (miscellaneous)

Reference28 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3