The size and shape of the focal spot, i.e. the area where x-rays are generated in an x-ray tube, is a key figure of merit of a radiographic imaging system, because it governs the achievable resolution and, if the shape is irregular, can introduce anisotropic blur in the radiographs. Size and shape are mainly determined by the diameter of the accelerated electron-beam and electron interactions with the target material. Since focal spot parameters change over time, due to target wear and drift in the electron optics, traceable methods to monitor the focal spot size and shape are required. Here, we present a method to map the 2D intensity distributions of focal spots, ranging from sub-microfocus (0.1 µm) to mesofocus (>50 μm). The method evaluates radial profiles of a circular aperture and applies filtered back projection to reconstruct the focal spot intensity distribution. Special emphasis is placed on traceability and influence factors, such as image noise and aperture geometry. The method was validated over a focal spot range from 0.3 µm to 200 µm. Experimental results were compared to complementary methods, using line pair gauges (JIMA) for microfocus (1 µm–10 µm), e-beam characterisation for sub-microfocus (0.3 µm–1.0 µm), and pinhole camera imaging for mesofocus spots (50 µm–200 µm). Good agreement between the focal spot reconstruction and the complementary methods was achieved. Limitations due to edge penetration, caused by the finite thickness of the circular aperture gauge, were experimentally verified. From these findings, we derived recommendations for an improved gauge geometry, regarding its thickness and the aperture diameters. The method perfectly complements the well-established pinhole imaging, which is limited to focal spots larger than ∼50 µm.
Funder
European Metrology Programme for Innovation and Research
Subject
Applied Mathematics,Instrumentation,Engineering (miscellaneous)
Reference25 articles.
1. Components and methods for highest resolution computed tomography;Uhlman,2008
2. Determination of metrological structural resolution of a CT system using the frequency response on surface structures;Fleßner,2014
3. Traceable measurement of the instrument transfer function in dXCT;Illemann,2020
4. Experimental investigation of the influencing factors on the structural resolution for dimensional measurements with CT systems;Arenhart,2016
5. Measuring the 3D resolution of a micro-focus x-ray CT setup;Weiß,2012
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献