Nanoparticle Characterization - Supplementary Comparison on Nanoparticle Size

Author:

Lin H -L,Fu W -E,Weng H -F,Misumi I,Sugawara K,Gonda S,Takahashi K,Takahata K,Ehara K,Takatsuji T,Fujimoto T,Salas J,Dirscherl K,Garnæs J,Damasceno J,Oliveira J C V de,Emanuele E,Picotto G B,Kim C S,Cho S J,Motzkus C,Meli F,Gao S,Shi Y,Liu J,JÄmting K,Catchpoole H J,Lawn M A,Herrmann J,Coleman V A,Adlem L,Kruger O A,Buajarern J,Buhr E,Danzebrink H -U,Krumrey M,Bosse H

Abstract

Nanoparticles with size in the range from 10 nm to 300 nm and from three different materials (Au 10 nm, Ag 20 nm, and PSL 30 nm, 100 nm and 300 nm) were used in this supplementary comparison. The selected nanoparticles meet the requirements of different measurement methods such as Atomic Force Microscopy (AFM), Transmission Electron Microscopy (TEM), Scanning Electron Microscopy (SEM), Dynamic Light Scattering (DLS), and Differential Mobility Analyzer (DMA), Small Angle X-Ray Scattering and for forth. All 37 participating laboratories returned results, but not all laboratories were able to perform measurement of all 5 nanoparticles. In order to determine the degree of equivalence (DOE), two reference values were considered in this comparison: the method dependent reference value (MRV) and the global reference value (GRV). The MRVs were determined for different measurement methods according to the corresponding reported uncertainties and measurement values from the participants. Each measurement method owns its own MRV. Since the measurement data from DLS were very different from and inconsistent with the measurement data from the other methods, the MRV for DLS was used in the En number calculation for the measurement data reported from the DLS method. The GRV was determined from the MRVs and their uncertainties of all the measurement methods except DLS, and was applied in the En number calculations for the measurement data reported from AFM, EM, DMA and SAXS methods. The assumption that the particles are spherical was commonly made in the nanoparticle measurements. Non-sphericity of particles, if exists, could have different impacts on different measurement methods. It is also important to note that the methods used are measuring mean diameters of a population of particles, not just a single particle, and that the meaning of the mean diameter could differ for different methods. Probably if participants include a different specific contribution in the uncertainty in a harmonized way, taking the non-cancelled method-dependent "systematic" errors into account, it may be easier to compare the results. KEY WORDS FOR SEARCH Nanoparticles; Atomic Force Microscopy (AFM); Transmission Electron Microscopy (TEM); Scanning Electron Microscopy (SEM); Dynamic Light Scattering (DLS); and Differential Mobility Analyzer (DMA); Small Angle X-Ray Scattering Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Publisher

IOP Publishing

Subject

General Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3