Author:
Zhang Rui,Zhang Wendong,He Changde,Song Jinlong,Mu Linfeng,Cui Juan,Zhang Yongmei,Xue Chenyang
Abstract
Purpose
– The purpose of this paper was to develop a novel capacitive micromachined ultrasonic transducer (CMUT) reception and transmission linear array for underwater imaging at 400 kHz. Compared with traditional CMUTs, the developed transducer array offers higher electromechanical coupling coefficient and higher directivity performance.
Design/methodology/approach
– The configuration of the newly developed CMUT reception and transmission array was determined by the authors’ previous research into new element structures with patterned top electrodes and into directivity simulation analysis. Using the Si-Silicon on insulator (Si-SOI) bonding technique and the principle of acoustic impedance matching, the CMUT array was fabricated and packaged. In addition, underwater imaging system design and testing based on the packaged CMUT 1 × 16 array were completed.
Findings
– The simulation results showed that the optimized CMUT array configuration was selected. Furthermore, the designed configuration of the CMUT 1 × 16 linear array was good enough to guarantee high angular resolution. The underwater experiments were conducted to demonstrate that this CMUT array can be of great benefit in imaging applications.
Practical implications
– Based on our research, the CMUT linear array has good directivity and good impedance matching with water and can be used for obstacle avoidance, distance measurement and imaging underwater.
Originality/value
– This research provides a basis for CMUT directivity theory and array design. CMUT array presented in this paper has good directivity and has been applied in the underwater imaging, resulting in a huge market potential in underwater detection systems.
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering
Reference21 articles.
1. Azar, L.
,
Shi, Y.
and
Wooh, S.C.
(2000), “Beam focusing behavior of linear phased arrays”,
NDT and E International
, Vol. 33 No. 3, pp. 189-198.
2. Cetin, A.M.
and
Bayram, B.
(2013), “Diamond-based capacitive micromachined ultrasonic transducers in immersion”,
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, Vol. 60 No. 2, pp. 414-420.
3. Cheng, X.Y.
(2008),
Minimally Invasive Capacitive Micromachined Ultrasonic Transducers Array for Biomedical Applications
, The University of New Mexico Press, New Mexico, Chapter 2, pp. 32-47.
4. Du, G.H.
,
Zhu, Z.M.
and
Gong, X.F.
(2012),
Acoustics Foundation
, 3rd ed., Nanjing University Press, Nanjing, pp. 222-223.
5. Emadi, T.A.
and
Buchanan, D.A.
(2015), “A novel 6 × 6 element MEMS capacitive ultrasonic transducer with multiple moving membranes for high performance imaging applications ⋆”,
Sensors and Actuators A: Physical
, Vol. 222 No. 1, pp. 309-313.
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献