Author:
Xiao Xiao,Müller Fabian,Nell Martin Marco,Hameyer Kay
Abstract
Purpose
The ordinary vector hysteresis stop model with constant threshold values is not able to prohibit the hysteretic property after the saturation correctly. This paper aims to develop an improved vector hysteresis stop model with threshold surfaces. This advanced anisotropic vector hysteresis stop model can represent the magnetic saturation properties and the hysteresis losses under alternating and rotating magnetizations.
Design/methodology/approach
By integrating anhysteretic surfaces into the elastic element of a vector hysteresis stop model, the anisotropy of the permeability of an electrical steel sheet can be represented. Instead of the commonly used constant threshold value for plastic elements of the hysteresis model, threshold surfaces are applied to the stop hysterons. The threshold surfaces can be derived directly from measured alternating major loops of the material sample. By saturated polarization, the constructed threshold surfaces are vanishing. In this way, the reversible magnetic flux density is in the same direction of the applied magnetic flux density. Thus, the saturation properties are satisfied.
Findings
Analyzing the measurements of the electrical steel sheets sample obtained from a rotational single sheet tester shows that the clockwise (CW) and counter-CW (CCW) rotational hysteresis losses decrease by saturated flux density. At this state, instead of the domain wall motion, the magnetization rotation is dominant in the material. As a result, the hysteresis losses, which are related to the domain wall motion, are vanished near the saturation. In one stop operator, the plastic element represents the hysteresis part of the model. Integrating threshold surface into the plastic element, the hysteresis part can be modified to zero near the saturation to represent the saturation properties.
Originality/value
The results of this work demonstrate that the presented vector hysteresis stop model allows simulation of anisotropic hysteresis effects, alternating and rotating hysteresis losses. The parameters of the hysteresis model are determined by comparing the measured and modeled minor loops in different alternating magnetization directions. With the identified parameters, the proposed model is excited with rotated excitations in CW and CCW directions. The rotated hysteresis losses, derived from the model, are then compared with those experimentally measured. The modified vector stop model can significantly improve the accuracy of representing hysteresis saturations and losses.
Subject
Applied Mathematics,Electrical and Electronic Engineering,Computational Theory and Mathematics,Computer Science Applications
Reference18 articles.
1. A new and robust hysteresis modeling based on simple equations;IEEE Transactions on Magnetics,2018
2. Magnetic anisotropy under arbitrary excitation in finite element models;Archives of Electrical Engineering,2019
3. Magnetic vector hysteresis model with friction-like pinning;Physica B: Condensed Matter,1997
4. A phenomenological differential‐relation‐based vector hysteresis model;Journal of Applied Physics,1994
5. Experimental testing of an anisotropic vector hysteresis model;IEEE Transactions on Magnetics,1997
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献