Author:
Wong L.T.,Mui K.W.,Hui P.S.
Abstract
PurposeThe purpose of this paper is to examine the air pressure variations in an in‐use drainage stack of high‐rise residential buildings with the probable influence of occupant loads.Design/methodology/approachThe air pressure variations in a drainage stack of a typical in‐use high‐rise residential building in Hong Kong were correlated to the number of water closet (WC) flushes of the building. In particular, measured diurnal WC flushing patterns of the residential buildings were used to correlate the diurnal pressure variations measured at 16 m above the stack base in a 115 m high, 150 mm diameter fully vented drainage stack of a typical high‐rise residential building of Hong Kong.FindingsThe occurrence of the maximum air pressure in the stack could be correlated with the expected hourly WC flushes of the high‐rise residential buildings with mathematical demonstrations.Research limitations/implicationsThere may be high speed transients in the stack (>1 hertz) which was not measured.Originality/valueThe result would be a useful source of reference for the development of control strategies against probable appliance seal loss in high‐rise residential buildings.
Subject
Building and Construction,Architecture,Human Factors and Ergonomics
Reference15 articles.
1. Campbell, D.P. and Macleod, K.D. (2001), “Detergents in drainage systems for buildings”, Water Research, Vol. 35 No. 4, pp. 1086‐92.
2. Cheng, C.L., Lu, W.H. and Shen, M.D. (2004), “An empirical approach: prediction method of air pressure distribution on building vertical drainage stack”, Journal of the Chinese Institute of Engineers, Vol. 28 No. 2, pp. 205‐17.
3. Fernandes, V.M.C. and Goncalves, O.M. (2006), “Limits for use of vent elements in building drainage systems considering the risk of infection spread by means of water‐seal behaviour and integrity: the case of Brazilian systems”, Building Services Engineering Research and Technology, Vol. 27 No. 2, pp. 103‐17.
4. Friedler, E., Butler, D. and Brown, D.M. (1996), “Domestic WC usage patterns”, Building and Environment, Vol. 31 No. 4, pp. 385‐92.
5. Gormley, M. (2006), “Solids in building drainage stacks: a potential cause of air pressure transients?”, Proceedings of the 32nd International Symposium on Water Supply and Drainage for Buildings, 1‐12. CIBW062. National University of Science and Technology (NTUST), Taipei, Taiwan, Section E2.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献