Author:
Zhuang Jinlei,Li Ruifeng,Cao Chuqing,Gao Yunfeng,Wang Ke,Wang Feiyang
Abstract
Purpose
This paper aims to propose a measurement principle and a calibration method of measurement system integrated with serial robot and 3D camera to identify its parameters conveniently and achieve high measurement accuracy.
Design/methodology/approach
A stiffness and kinematic measurement principle of the integrated system is proposed, which considers the influence of robot weight and load weight on measurement accuracy. Then an error model is derived based on the principle that the coordinate of sphere center is invariant, which can simultaneously identify the parameters of joint stiffness, kinematic and hand-eye relationship. Further, considering the errors of the parameters to be calibrated and the measurement error of 3D camera, a method to generate calibration observation data is proposed to validate both calibration accuracy and parameter identification accuracy of calibration method.
Findings
Comparative simulations and experiments of conventional kinematic calibration method and the stiffness and kinematic calibration method proposed in this paper are conducted. The results of the simulations show that the proposed method is more accurate, and the identified values of angle parameters in modified Denavit and Hartenberg model are closer to their real values. Compared with the conventional calibration method in experiments, the proposed method decreases the maximum and mean errors by 19.9% and 13.4%, respectively.
Originality/value
A new measurement principle and a novel calibration method are proposed. The proposed method can simultaneously identify joint stiffness, kinematic and hand-eye parameters and obtain not only higher measurement accuracy but also higher parameter identification accuracy, which is suitable for on-site calibration.
Subject
Industrial and Manufacturing Engineering,Computer Science Applications,Control and Systems Engineering
Reference19 articles.
1. Comparison of two calibration methods for a small industrial robot based on an optical CMM and a laser tracker;Robotica,2014
2. The parameter identification model considering both geometric parameters and joint stiffness;Industrial Robot: The International Journal of Robotics Research and Application,2020
3. Review on kinematics calibration technology of serial robots;International Journal of Precision Engineering and Manufacturing,2014
4. Development and verification of a novel robot-integrated fringe projection 3D scanning system for large-scale metrology;Sensors,2017
5. Robot calibration—method and results;Robotics and Computer-Integrated Manufacturing,1991
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献